The method of measuring corona current and ground field from lightning eliminator with multiple conductor points and lightning rod is given. The results of the measurement are reported. We can find that the corona current of lightning eliminator is basically equal to that of lightning rod, and either of them is smaller than 70 μA. This result shows that the lightning eliminator cannot provide electrification ions enough to neutralize the charges in thunderclouds, so the lightning eliminator is basically equal to that of lightning rod. The properties of ground field in the course of lightning are reported that can be helpful to understand the feature of lightning.
机译:给出了由具有多个导体点和避雷针的避雷器测量电晕电流和地场的方法。报告测量结果。可以发现,除雷器的电晕电流基本上等于避雷针的电晕电流,且二者均小于70μA。该结果表明,避雷器不能提供足够的带电离子来中和雷云中的电荷,因此该避雷器基本上等于避雷针。报道了雷电过程中地面场的特性,有助于理解雷电的特征。