...
首页> 外文期刊>Journal of athletic training >Interday reliability of peak muscular power outputs on an isotonic dynamometer and assessment of active trunk control using the chop and lift tests.
【24h】

Interday reliability of peak muscular power outputs on an isotonic dynamometer and assessment of active trunk control using the chop and lift tests.

机译:等渗测功机上峰值肌肉力量输出的日间可靠性,以及使用斩波和举重测试评估主动躯干控制。

获取原文
获取原文并翻译 | 示例
           

摘要

CONTEXT: Assessment techniques used to measure functional tasks involving active trunk control are restricted to linear movements that lack the explosive movements and dynamic tasks associated with activities of daily living and sport. Reliable clinical methods used to assess the diagonal and ballistic movements about the trunk are lacking. OBJECTIVE: To assess the interday reliability of peak muscular power outputs while participants performed diagonal chop and lift tests and maintained a stable trunk. DESIGN: Controlled laboratory study. SETTING: University research laboratory. PATIENTS OR OTHER PARTICIPANTS: Eighteen healthy individuals (10 men and 8 women; age = 32 +/- 11 years, height = 168 +/- 12 cm, mass = 80 +/- 19 kg) from the general population participated. INTERVENTION(S): Participants performed 2 power tests (chop, lift) using an isotonic dynamometer and 3 endurance tests (Biering-Sorensen, side-plank left, side-plank right) to assess active trunk control. Testing was performed on 3 different days separated by at least 1 week. Reliability was compared between days 1 and 2 and between days 2 and 3. Correlations between the power and endurance tests were evaluated to determine the degree of similarity. MAIN OUTCOME MEASURE(S): Peak muscular power outputs (watts) derived from a 1-repetition maximum protocol for the chop and lift tests were collected for both the right and left sides. RESULTS: Intraclass correlation coefficients for peak muscular power were highly reliable for the chop (range, 0.87-0.98), lift (range, 0.83-0.96), and endurance (range, 0.80-0.98) tests between test sessions. The correlations between the power assessments and the Biering-Sorensen test (r range, -0.008 to 0.017) were low. The side-plank tests were moderately correlated with the chop (r range, 0.528-0.590) and the lift (r range, 0.359-0.467) tests. CONCLUSIONS: The diagonal chop and lift power protocol generated reliable data and appears to be a dynamic test that simulates functional tasks, which require dynamic trunk control.
机译:背景:用于测量涉及主动躯干控制的功能性任务的评估技术仅限于缺乏爆炸性运动的线性运动以及与日常生活和体育活动相关的动态任务。缺乏用于评估躯干对角线和弹道运动的可靠临床方法。目的:评估参与者进行对角劈和举重测试并保持躯干稳定时峰值肌肉力量输出的日间可靠性。设计:对照实验室研究。地点:大学研究实验室。患者或其他参与者:18名健康人群(10名男性和8名女性;年龄= 32 +/- 11岁,身高= 168 +/- 12 cm,体重= 80 +/- 19 kg)。干预:参与者使用等渗测力计进行了2次力量测试(剁碎,提升)和3次耐力测试(Biering-Sorensen,左侧板,右侧板),以评估主动躯干控制。在间隔至少1周的3个不同日期进行测试。在第1天和第2天之间以及第2天和第3天之间比较了可靠性。评估了功效和耐力测试之间的相关性,以确定相似程度。主要观察指标:收集从右侧和左侧的一次重复最大量试验(对于一次斩波和推力测试)得出的峰值肌肉力量输出(瓦特)。结果:对于两次测试之间的印记(范围0.87-0.98),提升(范围0.83-0.96)和耐力(范围0.80-0.98),组内峰值肌肉力量的相关系数非常可靠。功效评估与Biering-Sorensen检验之间的相关性较低(r范围为-0.008至0.017)。侧板测试与排骨测试(r范围为0.528-0.590)和提升测试(r范围为0.359-0.467)具有中等相关性。结论:对角斩波和提升功率协议生成了可靠的数据,并且似乎是模拟功能任务的动态测试,需要动态树干控制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号