...
首页> 外文期刊>Circulation. Arrhythmia and electrophysiology >Cardiac resynchronization therapy device implantation using a new sensor-based navigation system: results from the first human use study.
【24h】

Cardiac resynchronization therapy device implantation using a new sensor-based navigation system: results from the first human use study.

机译:使用新的基于传感器的导航系统进行心脏再同步治疗设备的植入:首次人类使用研究的结果。

获取原文
获取原文并翻译 | 示例
           

摘要

Background- Cardiac resynchronization therapy (CRT) device implantation can be challenging, time consuming, and fluoroscopy intense. To facilitate left ventricular lead placement, a novel sensor-based electromagnetic tracking system (MediGuide Technology [MGT], St. Jude Medical) has been developed. We report the results of the First Human Use study evaluating the feasibility, safety, and performance of a novel CRT implantation approach using electromagnetic trackable operation equipment. Methods and Results- Fifteen consecutive patients (66±8 years, 53% male) with an established indication for CRT were implanted using the new tracking technology. Demographics, anatomical information, detailed fluoroscopy need, procedure time, and adverse events were collected. Patients were followed up for 4 weeks after implantation. The CRT system was successfully implanted with a lateral or posterolateral left ventricular lead position in all patients. The total procedure time was 116±43 minutes, the median total fluoroscopy time (skin to skin) was 5.2 (Q1-Q3, 3.0-8.4) minutes, and the median fluoroscopy time for left ventricular lead deployment (coronary sinus [CS] cannulation to withdrawal of CS sheath) measured 2.6 (Q1-Q3, 1.6-5.6) minutes. There were no severe complications that required an acute intervention or reoperation during the perioperative and postoperative periods. Conclusions- Use of the MGT tracking technology allows for safe and successful CRT implantation with the potential for reduced fluoroscopy time. Future randomized studies are needed to validate these data. Clinical Trial Registration- URL http://www.clinicaltrials.gov. Unique identifier: NCT01519739.
机译:背景技术心脏再同步治疗(CRT)装置植入可能具有挑战性,耗时且荧光检查强度很高。为了促进左心室导线的放置,已经开发了一种新型的基于传感器的电磁跟踪系统(MediGuide Technology [MGT],St。Jude Medical)。我们报告了首次人类使用研究的结果,该研究评估了使用电磁可跟踪操作设备的新型CRT植入方法的可行性,安全性和性能。方法和结果-使用新的跟踪技术植入了15例CRT确诊的连续患者(66±8岁,男性53%)。收集人口统计学,解剖学信息,详细的透视检查,手术时间和不良事件。植入后对患者进行了4周的随访。在所有患者中,CRT系统均成功植入了外侧或后外侧左心室导线位置。总手术时间为116±43分钟,平均透视时间(皮肤对皮肤)为5.2(Q1-Q3,3.0-8.4)分钟,透视时间为左心室铅部署(冠状窦[CS]插管)至撤回CS护套)的时间为2.6(Q1-Q3,1.6-5.6)分钟。在围手术期和术后没有严重的并发症需要紧急干预或再次手术。结论-使用MGT跟踪技术可以安全成功地进行CRT植入,并有可能缩短透视时间。需要未来的随机研究来验证这些数据。临床试验注册-URL http://www.clinicaltrials.gov。唯一标识符:NCT01519739。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号