首页> 外文期刊>Journal of AOAC International >Ultra-high performance liquid chromatography/electrospray ionization-tandem mass spectrometry determination of 151 pesticides in soybeans and pulses.
【24h】

Ultra-high performance liquid chromatography/electrospray ionization-tandem mass spectrometry determination of 151 pesticides in soybeans and pulses.

机译:超高效液相色谱/电喷雾串联质谱法测定大豆和豆类中的151种农药。

获取原文
获取原文并翻译 | 示例
           

摘要

This paper presents the application of ultra-high performance LC (UHPLC) and MS for the determination of 151 pesticides in soybeans and pulses. A core-shell particle (2.6 micro m particle size) column and a fully porous sub-2 micro m (1.7 micro m particle size) column showed comparable performance in chromatographic resolution and separation, increasing selectivity, and reducing analysis time. UHPLC was coupled with either a triple quadrupole mass analyzer (MS/MS) or a quadrupole Orbitrap (namely Orbital trap) mass spectrometer (Q-Orbitrap MS), which possesses fast data acquisition capability. Both configurations yielded analytical run times of <=14 min. Soybean and pulse samples were analyzed and quantitated for pesticide residues using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) procedure, UHPLC/electrospray ionization (ESI)-MS/MS, and matrix-matched standard calibration curves (in an analytical range of 5-500 micro g/kg) with isotopically-labeled standards or a chemical analog as internal standards. The method performance parameters that included overall recovery, intermediate precision, and measurement uncertainty were evaluated according to a nested design experiment. Approximately 89% of the pesticides studied had recoveries between 81 and 110%; 95%, had intermediate precision <=20%; and 93% showed measurement uncertainty <=40%. From a pilot study of 100 samples, eight tested positive by UHPLC/ESI-MS/MS for carbendazim, methomyl, or imidacloprid. These pesticides were further confirmed using UHPLC/ESI-Q-Orbitrap MS based on accurate mass measurement with mass error <=5 ppm.
机译:本文介绍了超高效液相色谱(UHPLC)和质谱(MS)在测定大豆和豆类中151种农药中的应用。核-壳型颗粒(2.6微米粒径)和完全多孔的亚2微米(1.7微米粒径)色谱柱在色谱分离和分离,增加的选择性和减少的分析时间方面表现出可比的性能。 UHPLC与具有快速数据采集能力的三重四极杆质量分析仪(MS / MS)或四极杆Orbitrap(即轨道阱)质谱仪(Q-Orbitrap MS)结合使用。两种配置的分析运行时间均小于等于14分钟。使用QuEChERS(快速,简便,廉价,有效,坚固和安全)程序,UHPLC /电喷雾电离(ESI)-MS / MS和基质匹配的标准校准曲线对大豆和豆类样品中的农药残留进行分析和定量同位素标记的标准品或化学类似物作为内标物的分析范围为5-500微克/千克)。根据嵌套设计实验评估了方法的性能参数,包括总体回收率,中间精度和测量不确定度。所研究的农药中约有89%的回收率在81%至110%之间。 95%,中等精度<= 20%; 93%的人表示测量不确定度<= 40%。在对100个样品的初步研究中,有8个样品通过UHPLC / ESI-MS / MS对多菌灵,灭多威或吡虫啉检测为阳性。使用UHPLC / ESI-Q-Orbitrap MS根据准确的质量测量结果进一步证实了这些农药,质量误差<= 5 ppm。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号