首页> 外文期刊>Journal of Aerosol Science >The measurement of liquid water mass associated with collected hygroscopic particles
【24h】

The measurement of liquid water mass associated with collected hygroscopic particles

机译:与收集的吸湿颗粒有关的液态水量的测量

获取原文
获取原文并翻译 | 示例
           

摘要

This work presents the measurements of aerosol liquid water (LW) mass of NH4NO3, NaNO3, NH4HSO4, and NaCI using a newly developed method (Lee and Hsu (1998) J.Aerosol. Sri. 29, 827-837) for the changing relative humidity (RH) at a stable room temperature. The target aerosol was generated by atomizing the 1.5% (wt/wt) solution of a known chemical and was subsequently collected on a Teflon filter. The four inorganic salts selected in this work were all hygroscopic, but their humidographs showed either with or without a hysteresis phenomenon. The NH4NO3 particles deliquesce at around 62% RH and re-crystallize at 32% RH with a gradual decline of L W mass. In contrast, the NaCI particles show a distinctive re-crystallization point at 47% RH and a deliquescent relative humidity (DRH) at around 76%. For NaNO3 and NH4HSO4 particles, no hysteresis effect was observed during the hydration and dehydration processes. A check on the evaporative loss of NH4NO3 particles showed no significant variation in the measurement of L W mass in 24 h. The comparison of the humidographs between sea salt and N aCI particles reveals that the amount of water uptake from sea salt is higher than that of the NaCI on a mol basis. The measured data and two humidographs from previous work were compared with a model calcu- lation. A good agreement was found for most salts except for (NH4)2S04 in the descending RH mode and NaCI in the ascending and descending RH modes. Finally, the effects of filter substrate on particles are discussed on the contact angle, particle agglomeration, and mass loading.
机译:这项工作介绍了使用新开发的方法(Lee和Hsu(1998)J.Aerosol.Sri.29,827-837)测量NH4NO3,NaNO3,NH4HSO4和NaCl的气溶胶液态水(LW)质量在稳定的室温下保持湿度(RH)。通过雾化已知化学物质的1.5%(wt / wt)溶液生成目标气雾剂,然后将其收集在Teflon过滤器上。在这项工作中选择的四种无机盐都具有吸湿性,但它们的湿度计显示有或没有滞后现象。 NH4NO3颗粒在RH约62%处发生潮解,并在RH约32%RH下重结晶,随着L W质量的逐渐降低。相反,NaCl颗粒在47%RH下显示出独特的重结晶点,潮解相对湿度(DRH)在76%左右。对于NaNO3和NH4HSO4颗粒,在水合和脱水过程中没有观察到滞后效应。检查NH4NO3颗粒的蒸发损失后,发现24小时内L W质量的测量值无明显变化。海盐和N aCI颗粒之间的湿度计的比较表明,以摩尔计,从海盐中吸收的水量比NaCl的高。将测得的数据和之前工作的两台湿度计与模型计算进行了比较。对于大多数盐,除了在RH下降模式下的(NH4)2SO4和在RH上升和下降模式下的NaCl外,发现了很好的一致性。最后,讨论了滤膜对颗粒的影响,包括接触角,颗粒团聚和质量负载。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号