OBJECTIVE: This study investigated whether glucose readings from a sensor sampling in interstitial fluid differ substantially from blood glucose (BG) values measured at the same time. RESEARCH DESIGN AND METHODS: We have evaluated the relationship between BG and glucose extracted from interstitial fluid using the GlucoWatch (Cygnus, Redwood City, CA) biographer, a device that collects glucose from subcutaneous interstitial space through intact skin by application of a low electric current. We evaluated the relative change in the interstitial glucose (IG) signal (IGS) as measured by the biographer versus BG using a normalized two-point sensitivity index (NSI). RESULTS: The results show that biographer measures of IG differ in time and magnitude from the corresponding BG values. In particular, the biographer values were shifted in time due to instrumental and physiological lag. Results show an average total lag of 17.2 +/- 7.2 min for all subjects evaluated. The instrumental lag was 13.5 min, suggesting that physiological lag is approximately 5 min. In addition, when glucose was increasing, the change in IGS was less than that in BG, while when BG was decreasing, the change in IGS was greater than that in BG. CONCLUSIONS: Similar results have been reported for other measures of IG, suggesting that differences reflect physiological variation in glucose uptake, utilization, and elimination in blood and interstitial space. This further evidence of the difference between IG and BG should be considered when interpreting glucose measurements from devices that sample interstitial fluid.
机译:目的:本研究调查了从组织液中的传感器采样中获取的葡萄糖读数与同时测量的血糖(BG)值是否存在显着差异。研究设计和方法:我们使用GlucoWatch(Cygnus,Redwood City,CA)传记作者评估了BG与从组织液中提取的葡萄糖之间的关系,该设备通过施加低电流通过完整的皮肤从皮下组织间隙收集葡萄糖。我们使用标准化的两点敏感度指数(NSI)评估了传记作者对BG测量的间质葡萄糖(IG)信号(IGS)的相对变化。结果:结果表明,传记作者对IG的测量在时间和幅度上与相应的BG值不同。特别是,由于仪器和生理上的滞后,传记作者的值会随时间推移而变化。结果显示,所有评估对象的平均总延迟为17.2 +/- 7.2分钟。仪器延迟为13.5分钟,表明生理延迟约为5分钟。另外,当葡萄糖增加时,IGS的变化小于BG,而当BG减少时,IGS的变化大于BG。结论:对于其他的IG测量也有类似的结果报道,表明差异反映了葡萄糖在血液,组织间隙的摄取,利用和消除中的生理变化。在解释从对组织液采样的设备中进行的葡萄糖测量时,应考虑IG和BG之间差异的进一步证据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号