Exploitation results of seven RO plants for recovery and reuse of treated effluents in textile industries

机译:七家反渗透工厂用于纺织工业中已处理废水的回收和再利用的结果

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The paper comprises a case study on the implementation of the advance treatment process (ATP) in seven small-scale textile industries.The ATPs installed and commissioned are in compliance with the Statutory Board directions for recovery and reuse of treated effluent leading to zero effluent discharge.The textile effluents are treated in effluent treatment plants comprising a physicochemical option followed by biological activated sludge process,pressure sand filtration and activated carbon adsorption.The tertiary treated effluents (25-65 m3/d) are high in total dissolved solids,chlorides and hardness,and partly reused for washing screens,cloth and ash quenching.The tertiary treated effluent contained suspended solids and total dissolved solids in the range,4-30 mg/L and 1980-2682 mg/L,respectively,with COD concentrations in the range,125-410 mg/L and did not meet the stipulated standards for discharge into inland surface waters.A part of the tertiary treated effluent (4.0-9.5 m3/d) is routed to ATP for recovery of boiler feed quality water.The ATP comprises a multi-grade filter,ultrafiltration (UF) unit and a reverse osmosis (RO) unit.The multi-grade filter ensured complete removal of suspended solids with a marginal decrease in COD.The fouling index (b) for the feed to the ultrafiltration was estimated to be varying in the range 0.6-2.1 x 10~(-3) s-1.The UF operated at 200-300 kcals with 88-95% permeate recovery.This unit achieved 80-90% removal of BOD and COD and 65-90% removal of phosphates.The RO unit at a pressure range of 1270-1670 kPascals produced 68-84% permeate.The permeate characteristics conforms the boiler water quality as prescribed by the Indian Standards Institution for low-pressure drum type boilers.The pH of the recovered water was adjusted with alkali to pH 10-11 and mechanically deaerated for use in boilers.Recycle/reuse of tertiary treated effluents for various purposes and reuse of the recovered water from advance treatment process as boiler water make-up has resulted in a reduction in water requirements by 30-35% in each industry.
机译:该文件包括对七个小规模纺织行业实施先进处理过程(ATP)的案例研究.ATP的安装和调试均符合法定委员会关于回收和再利用处理废水以实现零排放的指示。纺织废水在废水处理厂进行处理,包括物理化学选择,生物活性污泥工艺,压力砂过滤和活性炭吸附。三级处理废水(25-65 m3 / d)的总溶解固体,氯化物和三次处理后的废水含有悬浮固体和总溶解固体,分别在4-30 mg / L和1980-2682 mg / L的范围内,COD浓度在范围为125-410 mg / L,不符合向内陆地表水排放的规定标准。部分经三次处理的废水(4.0-9.5 m3 / d)为路由到ATP以回收锅炉给水质量的水.ATP包括一个多级过滤器,超滤(UF)单元和一个反渗透(RO)单元。该多级过滤器可确保完全去除悬浮固体,同时减少了化学需氧量。超滤进料的结垢指数(b)估计在0.6-2.1 x 10〜(-3)s-1范围内变化。超滤在200-300 kcals下运行,渗透率为88-95%该装置可去除BOD和COD的80-90%,去除磷酸盐的65-90%.RO装置在1270-1670 kPascal的压力范围内产生68-84%的透过水,其透过特性符合锅炉水质根据印度标准协会对低压鼓式锅炉的规定,将回收水的pH值用碱调节至pH 10-11并进行机械脱气以用于锅炉中。三次处理废水的回收/再利用可用于各种目的并重复使用废水处理过程中回收的水补充后,每个行业的用水量减少了30-35%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号