Bench scale electrodeionization for high pressure boiler feed water

机译:用于高压锅炉给水的台式电去离子

获取原文
获取原文并翻译 | 示例

摘要

In this paper, a bench scale RO/EDI system for high pressure boiler feed water is reported. Technical and economical aspects were evaluated to determine whether RO/EDI system is feasible to replace existing ion exchange bed. The EDI module used in this study was all filled electrodeionization type with mixed bed ion exchange filler. All product quality of demin water produced by RO/EDI during bench scale test shows good water quality (conductivity: 0.3-0.4 us/cm; pH: around 6.3; silica: 0.00-0.01 ppm; and Na: <0.003 ppm), even better than existing demin water system specification (conductivity: <5 μs/cm; pH: 6.5-8.5; silica: <0.12 ppm; and Na: <0.3 ppm), except pH. Dissolved CO2 in water (HCO3~-) is a suspected substance which is present in RO/EDI product water that influences the pH. The specific water cost of RO/EDI was US$0.53/m~3 lower than existing ion exchange beds, US$0.66/m~3. The main operating costs were membrane replacement and electricity cost Long term performance of the RO/EDI system showed stable and high product quality even during periods when the feed solution has relatively high conductivity.
机译:本文报道了用于高压锅炉给水的台式RO / EDI系统。对技术和经济方面进行了评估,以确定RO / EDI系统是否可替代现有的离子交换床。在这项研究中使用的EDI模块都是用混合床离子交换填料填充的电去离子型。 RO / EDI在工作台规模测试期间生产的所有软水产品质量均显示出良好的水质(电导率:0.3-0.4 us / cm; pH:约6.3;二氧化硅:0.00-0.01 ppm; Na:<0.003 ppm),甚至优于现有的除盐水系统规格(电导率:<5μs/ cm; pH:6.5-8.5;二氧化硅:<0.12 ppm; Na:<0.3 ppm),pH除外。水中溶解的二氧化碳(HCO3-)是可疑物质,存在于RO / EDI产品水中,会影响pH值。 RO / EDI的单位水成本比现有的离子交换床低0.63美元/ m〜3,低0.53美元/ m〜3。主要的运营成本是膜更换和电力成本,即使在进料溶液具有相对较高的电导率期间,RO / EDI系统的长期性能仍显示出稳定且较高的产品质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号