Objectives: When metallic prosthetic appliances and dental fillings exist in the oral cavity, the appearance of metal-induced streak artefacts is not avoidable in CT images. The aim of this study was to develop a method for artefact reduction using the statistical reconstruction on multidetector row CT images. Methods: Adjacent CT images often depict similar anatomical structures. Therefore, reconstructed images with weak artefacts were attempted using projection data of an artefact-free image in a neighbouring thin slice. Images with moderate and strong artefacts were continuously processed in sequence by successive iterative restoration where the projection data was generated from the adjacent reconstructed slice. First, the basic maximum likelihood- expectation maximization algorithm was applied. Next, the ordered subset-expectation maximization algorithm was examined. Alternatively, a small region of interest setting was designated. Finally, the general purpose graphic processing unit machine was applied in both situations. Results: The algorithms reduced the metal-induced streak artefacts on multidetector row CT images when the sequential processing method was applied. The ordered subset-expectation maximization and small region of interest reduced the processing duration without apparent detriments. A general-purpose graphic processing unit realized the high performance. Conclusions: A statistical reconstruction method was applied for the streak artefact reduction. The alternative algorithms applied were effective. Both software and hardware tools, such as ordered subset-expectation maximization, small region of interest and generalpurpose graphic processing unit achieved fast artefact correction.
机译:目的:当口腔中存在金属假体和牙齿填充物时,在CT图像中不可避免地会出现金属引起的条纹伪影。这项研究的目的是开发一种利用多探测器行CT图像的统计重建来减少伪影的方法。方法:相邻的CT图像通常描绘相似的解剖结构。因此,尝试使用相邻薄片中无伪影图像的投影数据来尝试重建伪影较弱的图像。通过连续的迭代恢复对具有中等伪像和强伪像的图像进行连续连续处理,其中投影数据是从相邻的重建切片生成的。首先,应用基本的最大似然期望最大化算法。接下来,检查了有序子集期望最大化算法。或者,指定一个小兴趣区设置。最后,在两种情况下都使用了通用图形处理单元机器。结果:当应用顺序处理方法时,该算法减少了多探测器行CT图像上金属引起的条纹伪影。有序的子集期望最大化和感兴趣的小区域减少了处理时间,而没有明显的损害。通用图形处理单元实现了高性能。结论:统计重建方法用于减少条纹伪影。应用的替代算法是有效的。软件和硬件工具(例如,有序子集期望最大化,感兴趣的小区域和通用图形处理单元)均实现了快速伪像校正。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号