首页> 外文期刊>Vaccine >Comparison of plaque reduction neutralisation test (PRNT) and measles virus-specific IgG ELISA for assessing immunogenicity of measles vaccination
【24h】

Comparison of plaque reduction neutralisation test (PRNT) and measles virus-specific IgG ELISA for assessing immunogenicity of measles vaccination

机译:减少斑块中和试验(PRNT)和麻疹病毒特异性IgG ELISA评估麻疹疫苗免疫原性的比较

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND: Plaque reduction neutralisation test (PRNT) is a gold standard assay for measles antibodies. PRNT, however, is time-consuming and more difficult to standardise than ELISA. METHODS: PRNT results were obtained on pre- and post-vaccination sera from 501 measles-vaccinated infants. From this cohort a sub-set of 210 infants were selected for testing by ELISA, which was performed either manually or by an automated processor. Results were corrected for sampling proportion before comparing the assays. RESULTS: Seroconversion was detected by PRNT in 454 infants of whom 324 were estimated to have seroconverted by manual ELISA and 191 by automated ELISA It is recommended that ELISA negative post-vaccination samples are re-tested by PRNT to detect all seroconversions.
机译:背景:斑块减少中和试验(PRNT)是麻疹抗体的金标准检测方法。但是,PRNT比ELISA耗时且更难以标准化。方法:从501例麻疹疫苗接种的婴儿的接种前后血清中获得PRNT结果。从该队列中,选择了210个婴儿的子集进行ELISA测试,可通过手动或自动处理器进行。在比较分析之前,将结果校正为采样比例。结果:PRNT检测了454例婴儿的血清转化,其中324例通过手动ELISA进行了血清转化,而191例通过自动ELISA进行了血清转化。建议通过PRNT重新检测ELISA阴性的疫苗接种后样本以检测所有血清转化。