首页> 外文期刊>Magnetic resonance imaging: An International journal of basic research and clinical applications >Interrelationships between 3-T-MRI-derived cortical and trabecular bone structure parameters and quantitative-computed-tomography-derivedbone mineral density
【24h】

Interrelationships between 3-T-MRI-derived cortical and trabecular bone structure parameters and quantitative-computed-tomography-derivedbone mineral density

机译:3-T-MRI衍生的皮质和小梁骨结构参数与定量计算机断层扫描衍生的骨密度之间的相互关系

获取原文
获取原文并翻译 | 示例
           

摘要

Recently, 3-T magnetic resonance imaging (MRI) has been introduced for bone imaging. Through higher signal-to-noise ratios, as compared to 1.5-T MRI, it promises to be a more powerful tool for the assessment of cortical and trabecular bone measures. The goal of our study was to compare MRI-derived cortical and trabecular bone measures to quantitative computed tomography (QCT)-derived bone mineral density (BMD). Using 3-T MRI in 51 postmenopausal women, apparent (app.) measures of bone volume/total volume, trabecular number (Tb.N), trabecular thickness (Tb.Th) and trabecular separation were derived at the distal radius, distal tibia and calcaneus. Cortical thickness (Ct.Th) was calculated at the distal radius and distal tibia. These measures were compared to QCT-derived BMD of the spine, hip and radius. Significant correlations (~?P<.05; ~(**)P<.001; ~(***)P<.0001) were found between spine BMD- and MRI-derived Ct.Th (r_(radius)=.55, ~*P<.05; r_(tibia)=.67, ~(***)P<.0001) and app. Tb.N (r_(radius)=.33, ~*P<.05; r_(tibia)=.35, ~*P<.05) at the radius and tibia. Furthermore, within the first 10 mm at the radius, an inverse correlation for Ct.Th and app. BV/TV (r_(6mm)=-.56, P<.001; r_(10mm)=-.36, P<.05) and app. Tb.Th (r_(6mm)=-.54, P<.001; r_(10mm)=-.41, P<.05) was found.
机译:近来,已经将3-T磁共振成像(MRI)用于骨成像。与1.5-T MRI相比,通过更高的信噪比,它有望成为评估皮质和小梁骨测量结果的更强大工具。我们研究的目的是将MRI衍生的皮质骨和小梁骨测量与定量CT成像(QCT)衍生的骨矿物质密度(BMD)进行比较。使用51位绝经后妇女的3-T MRI,从远端radius骨,胫骨远端获得了明显的(见)骨体积/总体积,小梁数(Tb.N),小梁厚度(Tb.Th)和小梁间隔的测量值和跟骨。计算远端radius骨和胫骨远端的皮质厚度(Ct.Th)。将这些测量值与源自QCT的脊柱,髋部和radius骨的BMD相比较。在脊柱BMD和MRI衍生的Ct.Th(r_(半径)==)之间发现了显着的相关性(〜?P <.05;〜(**)P <.001;〜(***)P <.0001) .55,〜* P <.05; r_(胫骨)=。67,〜(***)P <.0001)和app。在半径和胫骨处为Tb.N​​(r_(半径)=。33,〜* P <.05; r_(胫骨)=。35,〜* P <.05)。此外,在半径的前10 mm以内,Ct.Th与app呈反相关。 BV / TV(r_(6mm)=-。56,P <.001; r_(10mm)=-。36,P <.05)和app。发现Tb.Th(r_(6mm)=-。54,P <.001; r_(10mm)=-。41,P <.05)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号