The individual as well as the synergistic effect of depolarisers, such as H_2SO_3 (aq) and/or Fe~(2+) (aq) and/or Co~(2+) (aq) on copper electrodeposition has been studied. A comparison is made of their relative effects on anode potential, cell potential, current efficiency (CE), power consumption and deposit quality. Linear sweep voltammetry (LSV) has been used to study the cathodic and the anodic behaviours of the depolarisers during electrodeposition of copper. The lowest value in anode potential is observed in the presence of H_2SO_3 and Fe~(2+) (aq) together. The presence of either added Fe~(2+) (aq) or added Co~(2+) (aq) or both together polarises the cathode deposition potential of copper; the extent of polarisation is more prominent in the presence of only Fe~(2+) (aq). In contrast, the cathode deposition potential of copper is depolarised in the presence of H_2SO_3 in the electrolyte; the depolarisation increases when Fe~(2+) (ac) is added to the electrolyte containing sulfurous acid. X-ray diffraction data show the change in the relative growth on the preferred orientations of cathode copper deposits in the absence and the presence of H_2SO_3 (aq) and/or Fe~(2+) (aq) and/or Co~(2+) (aq) in the electrolyte solution. Scanning electron microscopy (SEM) results establish different surface morphology of the copper samples deposited in the presence of H_2SO_3/Fe~(2+) (aq)/Co~(2+) (aq)/Fe~(2+) (aq) + Co~(2+) (aq)/H_2SO_3 + Fe~(2+) (aq)/H_2SO_3 + Co~(2+) (aq)/H_2SO_3 + Fe~(2+) (aq) + Co~(2+) (aq) in the electrolyte solution.
机译:研究了去极化剂如H_2SO_3(aq)和/或Fe〜(2+)(aq)和/或Co〜(2+)(aq)对铜电沉积的个体作用和协同作用。比较它们对阳极电势,电池电势,电流效率(CE),功耗和沉积质量的相对影响。线性扫描伏安法(LSV)已用于研究在铜电沉积过程中去极化器的阴极和阳极行为。在H_2SO_3和Fe〜(2+)(aq)共同存在时,观察到阳极电位的最低值。添加的Fe〜(2+)(aq)或添加的Co〜(2+)(aq)或两者同时存在会极化铜的阴极沉积电位。仅存在Fe〜(2+)(aq)时,极化程度更为突出。相反,在电解质中存在H_2SO_3的情况下,铜的阴极沉积电位被去极化。当Fe〜(2+)(ac)添加到含亚硫酸的电解液中时,去极化增加。 X射线衍射数据表明,在不存在和存在H_2SO_3(aq)和/或Fe〜(2+)(aq)和/或Co〜(2)的情况下,阴极铜沉积物的优选取向的相对生长变化+)(水溶液)在电解液中。扫描电子显微镜(SEM)结果建立了H_2SO_3 / Fe〜(2+)(aq)/ Co〜(2+)(aq)/ Fe〜(2+)(aq )+ Co〜(2+)(水溶液)/ H_2SO_3 + Fe〜(2+)(水溶液)/ H_2SO_3 + Co〜(2+)(水溶液)/ H_2SO_3 + Fe〜(2+)(水溶液)+ Co〜电解液中的(2+)(水溶液)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号