首页> 外文期刊>HVAC&R research >Predicting backdrafting and spillage for natural-draft gas combustion appliances: A validation of VENT-II
【24h】

Predicting backdrafting and spillage for natural-draft gas combustion appliances: A validation of VENT-II

机译:预测天然气燃烧设备的回风和溢出:VENT-II的验证

获取原文
获取原文并翻译 | 示例

摘要

VENT-II is a computer program designed to provide detailed analysis of natural-draft and induced-draft combustion appliance vent systems (i.e., furnace or water heater). This program is capable of predicting house depressurization thresholds that lead to backdrafting and spillage of combustion appliances; however, validation reports of the program being applied for this purpose are not readily available. The purpose of this article is to assess VENT-II's ability to predict combustion gas spillage events due to house depressurization by comparing VENT-II simulated results with experimental data for four appliance configurations. The results show that VENT-II correctly predicts depressurizations resulting in spillage for natural draft appliances operating in cold and mild outdoor conditions but not for hot conditions. In the latter case, the predicted depressurizations depend on whether the vent section is defined as part of the vent connector or the common vent when setting up the model. Overall, the VENT-II solver requires further investigation before it can be used reliably to predict spillage caused by depressurization over a full year of weather conditions, especially where hot conditions occur.
机译:VENT-II是一种计算机程序,旨在提供对自然通风和诱导通风燃烧设备通风系统(即熔炉或热水器)的详细分析。该程序能够预测导致减压装置回流和燃烧设备泄漏的房屋减压阈值;但是,尚无法获得为此目的应用的程序的确认报告。本文的目的是通过将VENT-II仿真结果与四种设备配置的实验数据进行比较,来评估VENT-II预测由于房屋降压而导致的燃气泄漏事件的能力。结果表明,VENT-II可以正确预测降压导致在寒冷和中温室外条件下运行的自然通风设备泄漏,而在炎热条件下则不会泄漏。在后一种情况下,预测的降压取决于在建立模型时将排气口部分定义为排气口连接器的一部分还是普通排气口。总的来说,VENT-II解算器需要进一步研究,才能可靠地预测全年天气状况(特别是在炎热状况下)的降压引起的泄漏。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号