首页> 外文期刊>HVAC&R research >Theoretical performance comparison of CO{sub}2 transcritical cycle technology versus HCFC-22 technology for a military packaged air conditioner application
【24h】

Theoretical performance comparison of CO{sub}2 transcritical cycle technology versus HCFC-22 technology for a military packaged air conditioner application

机译:CO {sub} 2跨临界循环技术与HCFC-22技术在军事包装空调应用中的理论性能比较

获取原文
获取原文并翻译 | 示例
           

摘要

The world-wide agreement to restrict the use of chlorofluorocarbons (CFCs) and hydrofluorocarbons has prompted research into the possibilities of replacement refrigerants, particularly those occurring naturally in the environment. One such natural refrigerant, carbon dioxide, has been considered for certain refrigeration and air conditioning applications. In order to evaluate the potential performance of a refrigeration cycle based on carbon dioxide, a cycle model has been developed which can simulate the operation of a carbon dioxide based refrigerator/air conditioner. This model is called ACCO2 and accounts for the realistic effects of the thermo-physical properties of carbon dioxide. The model simulates the operation of a carbon dioxide based air conditioner that uses air as the heat source and heat sink. A parametric study has been conducted using ACCO2 as well as a validated cycle model which simulates the operation of an HCFC-22 based packaged air conditioner designed for use by the U.S. Army in a combat environment. The size and weight constraints of this application render HCFC-22 based units less efficient than typical HCFC-22 unitary air conditioners of the same capacity. It is hypothesized that these same constraints will not affect the performance of a carbon dioxide based packaged air conditioner as severely. The evaporative capacity, compressor power, and COP were calculated for each cycle over a range of indoor and outdoor temperatures, and used as a basis for comparing the two cycles.
机译:全世界范围内限制使用氯氟烃(CFC)和氢氟烃的协议促使人们研究替代制冷剂的可能性,尤其是在环境中自然产生的制冷剂。已经考虑将一种这样的天然制冷剂二氧化碳用于某些制冷和空调应用。为了评估基于二氧化碳的制冷循环的潜在性能,已经开发了一种循环模型,该模型可以模拟基于二氧化碳的冰箱/空调的运行。该模型称为ACCO2,说明了二氧化碳热物理性质的实际影响。该模型模拟使用空气作为热源和散热器的二氧化碳基空调的运行。已经使用ACCO2以及经过验证的循环模型进行了参数研究,该模型模拟了基于HCFC-22的成套空调的运行情况,该空调设计用于美国陆军在战斗环境中使用。此应用程序的尺寸和重量限制使基于HCFC-22的设备的效率不如具有相同容量的典型HCFC-22一体式空调器。假设这些相同的约束不会严重影响基于二氧化碳的包装空调的性能。计算室内和室外温度范围内每个循环的蒸发能力,压缩机功率和COP,并将其用作比较两个循环的基础。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号