首页> 外文期刊>Hip international: the journal of clinical and experimental research on hip pathology and therapy >Conversion of a long distally fixed uncemented revision femoral stem to a proximally fixed implant following fatigue fracture.
【24h】

Conversion of a long distally fixed uncemented revision femoral stem to a proximally fixed implant following fatigue fracture.

机译:在疲劳骨折后,将长的远端固定的非骨水泥翻修股骨柄转换为近端固定的植入物。

获取原文
获取原文并翻译 | 示例
           

摘要

There has been increasing focus on bone conservation through proximal fixation in primary hip arthroplasty. However, the debate regarding fixation in revision arthroplasty and which factors influence implant choice remains less clear-cut. We report a case involving fatigue fracture of a long, distally well-fixed, uncemented revision stem. This was revised to a proximally fixed implant. This case highlights a number of issues when considering the choice of implant in hip revision surgery and raises the issue of bone conservation in revision surgery. We would suggest that in both primary and revision hip arthroplasty meticulous pre-operative consideration of the choice of implant should be undertaken, especially in the younger patient with higher expectations and functional demands.
机译:通过近端固定在原发性髋关节置换术中越来越关注骨保护。然而,关于翻修置换术中的固定以及哪些因素影响植入物选择的争论仍然不那么清晰。我们报告了一例涉及远端长固定,未粘骨的翻修杆的疲劳性骨折。修改为近端固定植入物。当考虑在髋关节翻修手术中选择植入物时,该病例突出了许多问题,并提出了翻修手术中的骨保护问题。我们建议在髋关节置换术和翻修术中都应仔细考虑术前植入物的选择,尤其是在对期望和功能有更高要求的年轻患者中。