首页> 外文期刊>Health Physics: Official Journal of the Health Physics Society >USE OF TRANSPORTABLE RADIATION DETECTION INSTRUMENTS TO ASSESS INTERNAL CONTAMINATION FROM INTAKES OF RADIONUCLIDES PART II: CALIBRATION FACTORS AND ICAT COMPUTER PROGRAM
【24h】

USE OF TRANSPORTABLE RADIATION DETECTION INSTRUMENTS TO ASSESS INTERNAL CONTAMINATION FROM INTAKES OF RADIONUCLIDES PART II: CALIBRATION FACTORS AND ICAT COMPUTER PROGRAM

机译:使用可移动辐射检测仪器评估放射性核素的摄入引起的内部污染第二部分:校准因子和ICAT计算机程序

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The detonation of a radiological dispersion device or other radiological incidents could result in widespread releases of radioactive materials and intakes of radionuclides by affected individuals. Transportable radiation monitoring instruments could be used to measure radiation from gamma-emitting radionuclides in the body for triaging individuals and assigning priorities to their bioassay samples for in vitro assessments. The present study derived sets of calibration factors for four instruments: the Ludlum Model 44-2 gamma scintillator, a survey meter containing a 2.54 x 2.54-cm NaI(Tl) crystal; the Captus 3000 thyroid uptake probe, which contains a 5.08 x 5.08-cm NaI(Tl) crystal; the Transportable Portal Monitor Model TPM-903B, which contains two 3.81 x 7.62 x 182.9-cm polyvinyltoluene plastic scintillators; and a generic instrument, such as an ionization chamber, that measures exposure rates. The calibration factors enable these instruments to be used for assessing inhaled or ingested intakes of any of four radionuclides: Co-60, I-131, Cs-137, and Ir-192. The derivations used biokinetic models embodied in the DCAL computer software system developed by the Oak Ridge National Laboratory and Monte Carlo simulations using the MCNPX radiation transport code. The three physical instruments were represented by MCNP models that were developed previously. The affected individuals comprised children of five ages who were represented by the revised Oak Ridge National Laboratory pediatric phantoms, and adult men and adult women represented by the Adult Reference Computational Phantoms described in Publication 110 of the International Commission on Radiological Protection. These calibration factors can be used to calculate intakes; the intakes can be converted to committed doses by the use of tabulated dose coefficients. These calibration factors also constitute input data to the ICAT computer program, an interactive Microsoft Windows-based software package that estimates intakes of radionuclides and cumulative and committed effective doses, based on measurements made with these instruments. This program constitutes a convenient tool for assessing intakes and doses without consulting tabulated calibration factors and dose coefficients.
机译:放射线扩散装置的爆炸或其他放射线事件可能会导致放射性物质的广泛释放和受影响人员摄入放射性核素。可移动的辐射监测仪器可用于测量人体中发射伽玛射线的放射性核素的辐射,以对个体进行分类,并为其生物测定样本分配优先级,以进行体外评估。本研究得出了四种仪器的校准因子集:Ludlum 44-2型伽马闪烁体,一种包含2.54 x 2.54-cm NaI(Tl)晶体的测量仪; Captus 3000甲状腺摄取探针,其中包含5.08 x 5.08-cm NaI(Tl)晶体; TPM-903B型便携式门禁监控器,其中包含两个3.81 x 7.62 x 182.9-cm聚乙烯甲苯塑料闪烁体;还有一个通用仪器,例如电离室,它可以测量暴露率。校准因子使这些仪器可用于评估四种放射性核素(Co-60,I-131,Cs-137和Ir-192)中任何一种的吸入或摄入摄入量。这些推导使用了由橡树岭国家实验室开发的DCAL计算机软件系统中体现的生物动力学模型,以及使用MCNPX辐射传输代码的蒙特卡洛模拟。这三种物理仪器由以前开发的MCNP模型代表。受影响的个体包括以修订的Oak Ridge国家实验室的儿科幻象为代表的5岁儿童,以及以国际放射防护委员会第110号出版物中所述的成人参考计算幻象为代表的成年男性和成年女性。这些校准因子可用于计算摄入量;可以通过使用列表的剂量系数将摄入量转换为定剂量。这些校准因子还构成了ICAT计算机程序的输入数据,ICAT计算机程序是一个基于Microsoft Windows的交互式软件包,根据使用这些仪器进行的测量,可以估算放射性核素的摄入量以及累积和确定的有效剂量。该程序构成了评估摄入量和剂量的便捷工具,无需咨询列表中的校准系数和剂量系数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号