首页> 外文期刊>Heart rhythm: the official journal of the Heart Rhythm Society >Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: A systematic review and meta-analysis
【24h】

Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: A systematic review and meta-analysis

机译:射频消融过程中接触力传感技术的使用减少了心房颤动的复发:系统的回顾和荟萃分析

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The suboptimal outcomes of atrial fibrillation (AF) ablation have been attributed to lack of transmural lesions during pulmonary vein isoLation. The advent of contact force (CF) sensing technology enables real-time assessment of the applied force at the cathetertissue interface and increases the chances of transmural lesions. We sought to perform a meta-analysis of data from eligible studies to delineate the true impact of CF technology. Database searches through April 2015 identified 9 eligible studies (enrolling 1148 patients). The relative risk of AF recurrence at follow-up was used as the primary end point and assessed with random-effects metaanalysis. Radiofrequency (RE) duration, total procedure length, and fluoroscopy exposure were assessed as secondary outcomes using weighted mean difference with the random-effects model. Compared with standard technology, the use of CF technology showed a 37% reduction (relative risk 0.63; 95% confidence interval 0.44-0.91; P =.01) in AF recurrence at a median follow-up of 12 months and a 7.3-minute reduction (95% confidence interval -14.05 to -0.55; P =.03) in RE use during ablation. There was no significant difference in total procedure length and fluoroscopy exposure between the 2 groups. In conclusion, this meta-analysis shows that the use of CF technology decreases AF recurrence at a median follow-up of 12 months and also led to decreased use of RE during ablation. There was no difference in total procedure length and fluoroscopy exposure.
机译:心房颤动(AF)消融的次优结果归因于肺静脉隔离过程中缺乏透壁病变。接触力(CF)传感技术的出现使得能够实时评估导管组织界面处的作用力,并增加了透壁病变的机会。我们试图对符合条件的研究数据进行荟萃分析,以描述CF技术的真正影响。截至2015年4月的数据库搜索确定了9项合格研究(招募1148例患者)。随访时房颤复发的相对风险被用作主要终点,并通过随机效应荟萃分析进行评估。使用随机效应模型的加权平均差,将射频(RE)持续时间,总手术时间和透视检查作为次要结果进行评估。与标准技术相比,CF技术的AF复发减少了37%(相对风险0.63; 95%置信区间0.44-0.91; P = .01),中位随访12个月,随访7.3分钟消融期间使用RE减少(95%置信区间-14.05到-0.55; P = .03)。两组之间的总手术时间和荧光透视暴露无显着差异。总之,这项荟萃分析表明,使用CF技术可降低中位随访12个月的房颤复发率,并且还可减少消融期间RE的使用。总手术时间和透视检查无差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号