The effect of cross-sectional tenon geometry on static and cyclic load capacity of side chairs constructed with round-, rectangular-, and diamond-shaped mortise and tenon joints was investigated. Cyclic load capacity averaged about two-thirds of static load capacity for the joint configurations tested. For the configurations included in the test, chairs with mortise and tenon joints constructed with round-, rectangular-, and diamond-shaped tenons had static load to cyclic passing load ratios of 56.5, 66.8, and 69.2% for rectangular-, round-, and diamond-shaped tenons, respectively. These results indicate that useful relationships existed between static and cyclic performance of round mortise and tenon joints, which may simplify the design process for chairs that must pass cyclic performance tests.
机译:研究了横截面榫geometry几何形状对由圆形,矩形和菱形榫眼和榫on缝构造的侧椅的静态和循环载荷能力的影响。对于测试的接头配置,循环负载能力平均约为静态负载能力的三分之二。对于测试中包含的配置,带有榫眼和榫眼接头的椅子分别由圆形,矩形和菱形榫构造而成,矩形,圆形,圆形,矩形和圆形的静载荷与循环通过载荷之比分别为56.5、66.8和69.2%和菱形榫。这些结果表明,圆形榫眼和榫on接头的静态和循环性能之间存在有用的关系,这可以简化必须通过循环性能测试的椅子的设计过程。