首页> 外文期刊>Wear: an International Journal on the Science and Technology of Friction, Lubrication and Wear >Wear quantification of human enamel and dental glass-ceramics using white light profilometry
【24h】

Wear quantification of human enamel and dental glass-ceramics using white light profilometry

机译:使用白光轮廓仪对人类牙釉质和牙科玻璃陶瓷进行磨损定量

获取原文
获取原文并翻译 | 示例
       

摘要

The aim of this study was to develop a protocol for quantifying wear using white light profilometry. Human molar cusps and glass-ceramic disc (Ceramco-3, Ceramco, USA) surfaces were digitised using a non-contact profilometer (Proscan-2000, Scantron, UK) with an S16/3.5 white light sensor (Stil-S.A., France), before and after in vitro wear testing. Digitised images were superimposed using the dedicated software (Proform, Scantron, UK). Superimposed images were further processed in Proscan-2000 software to eliminate interferences with calculation of wear quantification parameters (volume, mean-height loss) by isolation of the worn area. Scanning repeatability and operator uncertainty introduced systematic errors that were also evaluated. The elimination of the areas surrounding the wear pattern produced significantly improved results for tooth (p<0.05) and glass-ceramic disc (p < 0.001) mean-height loss. Tooth volume loss accuracy was improved by 6.83% while disc volume loss was adequately calculated using the software's automated tool. Operator uncertainty tests produced mean (SD) mm~3 differences of 0.0040 (0.0023) for tooth specimens and 0.0013 (0.0007) for glass-ceramic disc specimens. Scanning repeatability tests produced mean (SD) mm~3 differences of 0.0024 (0.0007) for tooth specimens and 0.0030 (0.0015) for glass-ceramic disc specimens. The improved and repeatable measurements obtained may suggest a similar approach to be beneficial for similar applications and materials.
机译:这项研究的目的是开发一种使用白光轮廓测量法量化磨损的方案。使用具有S16 / 3.5白光传感器(Stil-SA,法国)的非接触轮廓仪(Proscan-2000,Scantron,英国)将人的臼齿和玻璃陶瓷盘(Ceramco-3,美国Ceramco)的表面数字化。 ,体外磨损测试前后。使用专用软件(Proform,Scantron,UK)叠加数字化图像。叠加的图像在Proscan-2000软件中进行了进一步处理,以通过隔离磨损区域消除对磨损量化参数(体积,平均身高损失)的计算的干扰。扫描的重复性和操作者的不确定性引入了系统性误差,这些误差也得到了评估。消除磨损模式周围的区域可显着改善牙齿(p <0.05)和玻璃-陶瓷圆盘(p <0.001)平均高度损失的结果。牙体积损失的准确性提高了6.83%,而使用该软件的自动工具可以充分计算出椎间盘的体积损失。操作者不确定性测试得出牙齿样本的平均(SD)mm〜3差异为0.0040(0.0023),玻璃陶瓷圆盘样本的平均值(SD)mm〜3差异为0.0013(0.0007)。扫描重复性测试得出牙齿样品的平均(SD)mm〜3差异为0.0024(0.0007),玻璃陶瓷圆盘样品为0.0030(0.0015)。获得的改进的和可重复的测量结果可能表明一种相似的方法对于相似的应用和材料是有益的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号