Kinetics of Carbon Tetrachloride biodegradation are evaluated in a continuous-flow fixed-biofilm reactor with controlled initial redox potential. The column was seeded with a mixed culture of indigenous microorganisms Pseudomonas cepacia and Providencia stuartii. The fixed biofilm reactor exhibited 98%-99.9% biodegradation of CT introduced into the reactor at an initial concentration of about 200 mu g/l for retention times of 1 to 4 days respectively. Four models were employed to evaluate the kinetics of CT biodegradation. These included: Eckenfelder (1989), Arvin (1991), Bouwer and McCarty (1985) and a biphasic model. Comparison of calculated results with observed results between these models agreed very closely to each other (0.968 < R-2 < 0.999). Predicted performance was best described by the model of Bouwer and McCarty (1985). However, the biphasic and Eckenfelder models provided excellent correlations and were much simpler to apply. The biphasic model yielded very good correlations of the data for all detention times evaluated; whereas, the Eckenfelder model effected comparable results only at the longer retention times studied. (C) 1998 IAWQ. Published by Elsevier Science Ltd. All rights reserved. [References: 10]
机译:在控制初始氧化还原电势的连续流固定生物膜反应器中评估四氯化碳生物降解的动力学。该柱上接种了本地微生物洋葱假单胞菌和斯氏普罗维登斯氏菌的混合培养物。固定生物膜反应器在初始浓度约为200μg / l的情况下,表现出引入反应器中的CT的98%-99.9%的生物降解,分别保留了1至4天。四个模型被用来评估CT生物降解的动力学。这些模型包括:Eckenfelder(1989),Arvin(1991),Bouwer和McCarty(1985)和双相模型。这些模型之间的计算结果与观察结果的比较彼此非常接近(0.968

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号