Microbial risk assessment of dental unit water systems in general dental practice in Greece

机译:希腊一般牙科实践中的牙科用水系统的微生物风险评估

获取原文
获取原文并翻译 | 示例
           

摘要

Water was sampled from source water, the 3-in-1 syringe and the air rotor water line of dental unit water systems (DUWS) in general dental practice in Attica, Greece. A section of the water line supplying the 3-in-1 syringe was cut for biofilm analysis. High total viable counts, Mycobacterium spp. and Pseudomonas aeruginosa were detected in the samples. Back siphonage was evidenced by the presence of blood and the recovery of oral anaerobes from the samples. Legionella pneumophila was recovered from 16.1% of biofilm samples. All tested disinfectants reduced the total viable counts of the DUWS to < 100 CFU/mL.
机译:在希腊阿提卡的常规牙科实践中,从原水,三合一注射器和牙科单位水系统(DUWS)的空气转子水管线中取样水。切断了向三合一注射器供水的管线的一部分,以进行生物膜分析。总活菌计数高,分枝杆菌属。样品中检出了铜绿假单胞菌和铜绿假单胞菌。血液的存在和样本中口腔厌氧菌的恢复证明了虹吸功能。从16.1%的生物膜样品中回收了嗜肺军团菌。所有经过测试的消毒剂都将DUWS的总生存量降低到<100 CFU / mL。