Effects of Implant Angulations and Attachment Configurations on the Retentive Forces of Locator Attachment-Retained Overdentures

机译:种植体的角度和附着结构对定位器附着保留义齿的固位力的影响

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Purpose: The aim of this study was to evaluate the effects of different implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures over a simulated time period of 6 months. Materials and Methods: Two acrylic resin models (models 1 and 2) were fabricated to represent an edentulous mandible. In model 1, the midline implant (in the central region) was vertical and the other two implants (in the canine regions) were 20 degrees divergent from the midline, reaching a total divergence of 40 degrees. In model 2, all three implants were vertically oriented, perpendicular to the occlusal plane and parallel to each other. Three-point vertical pull-out forces were employed in a universal testing machine at a constant crosshead speed of 50 mm/min after overdenture construction and a simulation of 6 months of repeated insertions/removals of the overdenture. Locator attachments with different male combinations and bar and clip attachments were tested in model 1. Clear locator attachments and bar and clip attachments were tested in model 2 and served as controls. Results: The initial retentive forces of all attachments in both models ranged from 26.58 to 62.05 N, whereas the initial retentive forces of the attachments for only model 1 ranged from 49.58 to 62.05 N. The highest retention value was recorded for clear green locator attachments and the lowest for hader bar yellow clip attachments. Locator attachments showed higher retention values than hader bar yellow clip attachments. Conclusion: All attachment systems demonstrated a decrease in retention over time. Locator attachments provided better retention than hader bar yellow clip attachments. The highest retention values were obtained when green male locators were used in combination with male attachments.
机译:目的:本研究的目的是评估在6个月的模拟时间内,不同植入物的角度和附着配置对定位器附着保留的覆盖义齿的固位力的影响。材料和方法:制作了两种丙烯酸树脂模型(模型1和2)来代表无牙颌。在模型1中,中线植入物(在中心区域)是垂直的,其他两个植入物(在犬齿区域)与中线发散20度,达到总发散度40度。在模型2中,所有三个植入物都是垂直定向的,垂直于咬合面并彼此平行。覆盖义齿之后,在通用测试仪中以50 mm / min的恒定十字头速度施加三点垂直拔出力,并模拟了6个月重复插入/移除覆盖义齿的过程。在模型1中测试了具有不同凸形组合的定位器附件以及杆和夹子附件。在模型2中测试了清晰的定位器附件以及杆和夹子附件,并将其用作对照。结果:在两个模型中,所有附件的初始保持力范围为26.58至62.05 N,而仅模型1的附件的初始保持力范围为49.58至62.05N。对于清晰的绿色定位器附件和最低的黄色条形夹附件。定位器附件显示的保留值比黑条黄色夹子附件高。结论:所有附件系统均显示保留率随时间降低。定位器附件比黑条黄色夹子附件具有更好的固定性。当绿色的雄性定位器与雄性附件结合使用时,可获得最高的保留值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号