首页> 外文期刊>The International journal of oral & maxillofacial implants >A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading.
【24h】

A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading.

机译:在评估标准负载和TiUnite单齿植入物在即时负载下的基本稳定性和最终扭矩容量时,比较切削扭矩和共振频率之间的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: In this study, standard Branemark System implants and Branemark TiUnite implants were evaluated regarding primary stability and placement torque. The correlation between placement torque and primary stability as well as the influence of implant design on placement torque and primary stability were examined. MATERIALS AND METHODS: Twelve patients who presented bilateral loss of either maxillary lateral incisors or premolars were treated with 24 immediately loaded dental implants. Each patient received 1 standard 3.75 x 13-mm Branemark System implant and one 3.75 x 13-mm TiUnite Mk III implant. One at a time, each implant was connected by a transducer to an Osstell machine that automatically translated a resonance frequency value for the implant into an implant stability quotient value. Osseocare equipment was used to measure the placement torque for both types of implants. RESULTS: Statistical analysis showed higher mean values for standard implants in relation to placement torque and resonancefrequency values. DISCUSSION: There was no overall correlation between placement torque and resonance frequency values; this finding supported previous studies. CONCLUSION: Stability was shown to be higher for the standard implants. Mean values of torque resistance were higher for the standard implants than for the TiUnite implants. Implant design appeared to influence primary stability and placement torque.
机译:目的:在这项研究中,评估了标准的Branemark系统植入物和Branemark TiUnite植入物的主要稳定性和放置扭矩。检查了放置扭矩和主要稳定性之间的相关性,以及植入物设计对放置扭矩和主要稳定性的影响。材料与方法:12例双侧上颌切牙或前磨牙双侧缺失的患者接受了24颗即刻负载的种植牙治疗。每位患者接受1枚标准3.75 x 13毫米Branemark系统植入物和1枚3.75 x 13毫米TiUnite Mk III植入物。一次将每个植入物通过换能器连接到Osstell机器,该机器会自动将植入物的共振频率值转换为植入物稳定性商值。 Osseocare设备用于测量两种植入物的放置扭矩。结果:统计学分析显示,相对于放置扭矩和共振频率值,标准植入物的平均值更高。讨论:放置扭矩和共振频率值之间没有整体相关性;这一发现支持了以前的研究。结论:标准植入物的稳定性更高。标准植入物的抗扭强度平均值高于TiUnite植入物。植入物设计似乎会影响主要稳定性和放置扭矩。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号