首页> 外文期刊>The International journal of oral & maxillofacial implants >Effect of implant abutment modification on the extrusion of excess cement at the crown-abutment margin for cement-retained implant restorations.
【24h】

Effect of implant abutment modification on the extrusion of excess cement at the crown-abutment margin for cement-retained implant restorations.

机译:种植体基台改型对多余的水泥在冠基台边界处挤出的影响,用于保留水泥的种植体修复体。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: To compare the effect of implant abutment modification on the amount of cement extruded at the crown-abutment margin and to evaluate the vertical discrepancy after cementation. MATERIALS AND METHODS: Access openings of titanium abutments were modified with an opening (open) and placement of two vent holes 3 mm from the occlusal edge and 180 degrees apart (internal vent). Access openings were filled with resin material (closed) and used as controls. Each abutment was secured to an implant analog. Eugenol-free zinc oxide cement (TempBond NE) was selected to cement the cast crowns (n = 9) onto test abutments. The amount of cement extruded out of the margin was calculated, and vertical seating discrepancies were determined with a linear transducer device before and after cementation. Differences among groups were analyzed statistically. RESULTS: The mean amount of extruded cement ranged from 36% to 90% of the total cement placed within the crowns. The order, from least to greatest amount of excess cement extrusion at the margins, was internal vent, open, and closed; significant differences were observed between test groups. The net vertical discrepancies of tested specimens ranged from -7 mum to +6 mum (mean, 0 mum). No statistically significant differences in vertical discrepancy were found between the groups. CONCLUSIONS: Venting the hollow abutment resulted in the least amount of cement extrusion when compared to closing off the screw access channel or leaving it open. Within the limitations of this study, it may be concluded that the use of two, 0.75-mm radius vent holes placed 3 mm apical to the occlusal area of the abutment and 180 degrees apart will limit the amount of cement extruded into the gingival sulcus of implant-retained crowns.
机译:目的:比较种植体基台改性对在冠基台边缘挤出的骨水泥量的影响,并评估骨水泥固位后的垂直差异。材料和方法:钛基台的检修口经过开孔(开口)的修改,并在距咬合边缘3 mm且相距180度的两个通气孔(内部通气孔)之间进行了布置。检修口用树脂材料填充(封闭)并用作对照。每个基台固定到植入物类似物上。选择不含丁香酚的氧化锌水泥(TempBond NE)将铸冠(n = 9)粘接到测试基台上。计算出从边缘挤出的水泥量,并在水泥化之前和之后使用线性换能器设备确定竖向落差。统计分析各组之间的差异。结果:挤出的水泥的平均量为冠内放置的全部水泥的36%至90%。在边缘处从最小量到最大量的过量水泥挤出的顺序是内部通风孔,打开和关闭。测试组之间观察到显着差异。测试样本的净垂直差异范围为-7微米至+6微米(平均为0微米)。两组之间在垂直差异方面没有统计学上的显着差异。结论:与封闭螺钉通道或使其保持打开相比,对空心基台进行排气可使水泥挤出量最少。在本研究的限制范围内,可以得出以下结论:使用两个半径为0.75 mm的排气孔,位于基台的咬合区域顶端3 mm并相隔180度,这将限制挤出到牙龈沟中的水泥量植入物保留的牙冠。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号