首页> 外文期刊>The International journal of oral & maxillofacial implants >Effect of splinted and nonsplinted impression techniques on the accuracy of fit of fixed implant prostheses in edentulous patients: a comparative study.
【24h】

Effect of splinted and nonsplinted impression techniques on the accuracy of fit of fixed implant prostheses in edentulous patients: a comparative study.

机译:夹层和非夹层印模技术对无牙颌患者固定植入假体的贴合精度的影响:一项比较研究。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: The effect of different implant impression techniques on the accuracy of casts has been investigated mostly in vitro, and clinically relevant evidence is scarce. The purpose of this study was to investigate the effect of implant impression techniques--specifically, splinted versus nonsplinted--on the accuracy of fit of fixed implant prostheses in edentulous patients. MATERIALS AND METHODS: This clinical study included 12 edentulous patients (13 edentulous arches). All patients had undergone computer-guided, prosthetically driven implant surgery. Splinted (with acrylic resin) and nonsplinted pickup implant impression techniques were used to generate two different casts. Intraoral verification jigs were made to fabricate a third index cast (prosthesis fabrication cast); these made up a control group. All patients were definitively rehabilitated with one-piece zirconia prostheses. The accuracy of fit of each prosthesis was evaluated indirectly by examining them clinically and radiographically while they were fit on the generated casts. RESULTS: Of the 13 splinted casts, 12 presented with accurate clinical fit when the zirconia prosthesis was seated on its respective cast. Only 6 of the 13 nonsplinted casts showed accurate clinical fit. The zirconia prostheses fit accurately on all respective casts of the control group (prosthesis fabrication cast) as well as intraorally. The differences between the test groups and between the nonsplinted and control groups were statistically significant. No statistically significant differences were found between the splinted and control groups. CONCLUSION: There is clinical evidence that the splinted impression technique generates more accurate implant impressions and master casts than the nonsplinted technique for complete-arch, one-piece fixed prostheses.
机译:目的:大多数在体外研究了不同的植入物印模技术对铸模准确性的影响,临床上缺乏相关的证据。这项研究的目的是研究种植体印模技术-特别是夹板与非夹板-对无牙颌患者固定式种植体修复的准确性。材料与方法:该临床研究包括12例无牙的患者(13例无牙弓)。所有患者均接受了计算机指导的假肢驱动的植入物手术。夹板(使用丙烯酸树脂)和非夹板的种植体压模技术用于生成两个不同的模型。制作口内验证夹具以制造第三指数铸件(假体制造铸件);这些组成了一个对照组。所有患者均用一件式氧化锆假体彻底修复。在将假体安装在生成的模型上的同时,通过临床和射线照相检查间接地评估了每个假体的安装精度。结果:在13个夹板型铸件中,当将氧化锆假体放置在其相应的铸件上时,有12个具有精确的临床适应性。 13个非夹板石膏中只有6个显示准确的临床拟合。氧化锆假体可以准确地安装在对照组的所有铸件(假体制造铸件)上以及口腔内。测试组之间以及非夹层组和对照组之间的差异具有统计学意义。在夹板组和对照组之间没有发现统计学上的显着差异。结论:有临床证据表明,对于完全弓形,整体式固定假体,夹板压印技术比非夹板压印技术能产生更准确的种植体压模和铸模。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号