...
首页> 外文期刊>Veterinary Radiology & Ultrasound >Effect of delayed acquisition times on gadolinium-enhanced magnetic resonance imaging of the presumably normal canine brain.
【24h】

Effect of delayed acquisition times on gadolinium-enhanced magnetic resonance imaging of the presumably normal canine brain.

机译:延迟的采集时间对推测正常的犬脑g增强磁共振成像的影响。

获取原文
获取原文并翻译 | 示例

摘要

A delay in imaging following intravenous contrast medium administration has been recommended to reduce misdiagnoses. However, the normal variation of contrast enhancement in dogs following a delay has not been characterized. Contrast-enhanced MR imaging of 22 dogs was assessed, in terms of identification of normal anatomic structures, to investigate the variation associated with 10-min delay between contrast medium administration and imaging. All dogs had a normal brain MR imaging study and unremarkable cerebrospinal fluid. Specific regions of interest were assessed both objectively, using computer software, and subjectively using three observers. Mean contrast enhancement >10% was seen in the pituitary gland, choroid plexus, meninges, temporal muscle, trigeminal nerve, and the trigeminal nerve root. Structures with an active blood-brain barrier had minimal contrast enhancement (<6%). Enhancing structures had significantly more contrast enhancement at t=1 min vs. t=10 min, except in temporal muscle, the trigeminal nerve and the trigeminal nerve root. Interobserver agreement was moderate to good in favor of the initial postcontrast T1-weighted (T1w) sequence. The observers found either no difference or poor agreement in identification of the nonvascular structures. Intraobserver agreement was very good with all vascular structures and most nonvascular structures. A degree of meningeal enhancement was a consistent finding. The initial acquisition had higher enhancement characteristics and observer agreement for some structures; however, contrast-to-noise was comparable in the delayed phase or not significantly different. We provide baseline references and suggest that the initial T1w postcontrast sequence is preferable but not essential should a delayed postcontrast T1w sequence be performed.Digital Object Identifier http://dx.doi.org/10.1111/j.1740-8261.2011.01847.x
机译:建议减少静脉造影剂给药后的影像学检查,以减少误诊。然而,延迟后狗的对比增强的正常变化尚未被表征。根据正常解剖结构的鉴定,评估了22只犬的造影剂MR成像,以研究与造影剂给药和成像之间10分钟延迟相关的变化。所有狗的脑部MR影像检查均正常,脑脊液无异常。使用计算机软件客观地评估感兴趣的特定区域,并使用三个观察者进行主观评估。在垂体,脉络丛,脑膜,颞肌,三叉神经和三叉神经根中观察到平均对比度增强> 10%。具有活跃的血脑屏障的结构具有最小的对比度增强(<6%)。除了在颞肌,三叉神经和三叉神经根中,增强结构在 t = 1分钟vs. t = 10分钟时具有明显更多的对比度增强。观察员之间的共识是中度到良好的,有利于初始的对比度后T1加权(T1w)序列。观察者发现在识别非血管结构上没有差异或一致性差。所有血管结构和大多数非血管结构的观察者内一致性都很好。脑膜增强的程度是一个一致的发现。初始购置对某些结构具有更高的增强特性和观察者同意;但是,在延迟阶段,噪声对比是可比的或没有显着差异。我们提供基线参考,并建议初始T1w对比度后序列是可取的,但如果执行延迟的对比度后T1w序列则不是必需的。数字对象标识符http://dx.doi.org/10.1111/j.1740-8261.2011.01847.x

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号