FEASIBILITY AND REPEATABILITY FOR IN VIVO MEASUREMENTS OF STIFFNESS GRADIENTS IN THE CANINE GASTROCNEMIUS TENDON USING AN ACOUSTOELASTIC STRAIN GAUGE

机译:使用声弹应变仪对犬胃肠道肌腱的刚度梯度进行体内测量的可行性和可重复性

获取原文
获取原文并翻译 | 示例
           

摘要

B-mode ultrasound is an established imaging modality for evaluating canine tendon injury. However, full extent of tendon injury often remains difficult to estimate, as small changes in sonographic appearance are associated with large changes in biomechanical strength. The acoustoelastic strain gauge (ASG) is an ultrasound-based tissue evaluation technique that relates the change in echo intensity observed during relaxation or stretching of tendons to the tissue's mechanical properties. This technique deduces stiffness gradient (the rate of change of normalized stiffness as a function of tissue strain) by analyzing the ultrasound dynamic images captured from gradually deforming tissue. ASG has been proven to accurately model strain and stiffness within tendons in vitro. To determine the feasibility and repeatability for in vivo ASG measurements of canine tendon function, stiffness gradients for the gastrocnemius tendons of 10 clinically normal dogs were recorded by two nonindependent observers at three sites (musculotendinous junction, mid tendon, and insertion). Average stiffness gradient indices (0.0132, 0.0141, 0.0136) and dispersion values (0.0053, 0.0054, 0.0057) for each site, respectively, were consistent with published mechanical properties for normal canine tendon. Mean differences of the average stiffness gradient index and dispersion value between observers and between limbs for each site were less than 16%. Using interclass coefficients (ICC), intra-observer (ICC 0.79-0.98) and interobserver (ICC 0.77-0.95) reproducibility was good to excellent. Right and left limb values were symmetric (ICC 0.74-0.92). Findings from this study indicated that ASG is a feasible and repeatable technique for measuring stiffness gradients in canine tendons.
机译:B型超声是用于评估犬肌腱损伤的既定成像方式。然而,肌腱损伤的完全程度通常仍然难以估计,因为超声检查外观的小变化与生物力学强度的大变化有关。声弹性应变仪(ASG)是一种基于超声的组织评估技术,该技术将在腱松弛或拉伸过程中观察到的回声强度的变化与组织的机械特性相关联。该技术通过分析从逐渐变形的组织中捕获的超声动态图像来推导刚度梯度(归一化刚度的变化率作为组织应变的函数)。事实证明,ASG可以在体外精确模拟肌腱内的应变和刚度。为了确定体内ASG测量犬肌腱功能的可行性和可重复性,由两名非独立观察员在三个位置(肌腱连接,中肌腱和插入)记录了10只临床正常狗的腓肠肌肌腱的刚度梯度。每个部位的平均刚度梯度指数(0.0132、0.0141、0.0136)和分散值(0.0053、0.0054、0.0057)与正常犬腱的已公布力学性能一致。每个站点的观察者之间以及肢体之间的平均刚度梯度指数和分散值的平均差小于16%。使用类间系数(ICC),观察者内(ICC 0.79-0.98)和观察者间(ICC 0.77-0.95)的重现性非常好。左右肢的值是对称的(ICC 0.74-0.92)。这项研究的结果表明,ASG是测量犬腱刚度梯度的可行且可重复的技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号