首页> 外文期刊>Veterinary Ophthalmology >Evaluation of the distance between Schwalbe's line and the anterior lens capsule as a parameter for the correction of ultrasound biomicroscopic values of the canine iridocorneal angle.
【24h】

Evaluation of the distance between Schwalbe's line and the anterior lens capsule as a parameter for the correction of ultrasound biomicroscopic values of the canine iridocorneal angle.

机译:评估Schwalbe线与晶状体前囊之间的距离,作为校正犬虹膜角膜角超声生物显微镜值的参数。

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: To determine whether the distance between Schwalbe's line (the peripheral termination of Descemet's membrane, i.e., the borderline between the cornea and sclera) and the anterior lens capsule (SLD) is an applicable parameter for correcting raw ultrasound biomicroscopic values of the canine iridocorneal angle (ICA) and to establish a comparative system for the ICA values in different canine breeds with varied body sizes/weights. Animal studied: The dogs were divided into four groups based on body weight (BW): <4 kg, 4-8 kg, 8-20 kg, and >20 kg, and 180 normotensive eyes were studied. Procedures: The ICA microstructure was examined by ultrasound biomicroscopy (UBM) using 40-MHz probes in dogs with or without anesthesia/sedation. Linear regression analysis and correlation coefficients were evaluated between SLD or SLD2 and UBM measurements; subsequently, noncorrected and SLD-corrected UBM values were statistically assessed. Results: Significant linear correlations were detected between SLD and the ciliary cleft width, the minimum distance between the angle recess and the scleral venous plexus, and the scleral thickness. Positive linear correlations were also demonstrated between SLD2 and the ciliary cleft area as well as the scleral venous plexus area. Raw UBM measurements were corrected by using a ratio with SLD on the distance or SLD2 on the area. Although noncorrected UBM measurements increased with canine BW, SLD-corrected UBM values remained similar with no significant statistical differences in any of the dogs. Conclusions: Correction with SLD would be clinically useful for comparing UBM measurements of the ICA in dogs with different body sizes/weights.
机译:目的:确定Schwalbe线(Descemet膜的周边末端,即角膜和巩膜之间的边界)与晶状体前囊(SLD)之间的距离是否可用于校正犬虹膜角膜的原始超声生物显微镜值角度(ICA),并建立不同体型/体重的不同犬种ICA值的比较系统。动物研究:根据体重(BW)将狗分为4组:<4 kg,4-8 kg,8-20 kg和> 20 kg,并研究了180​​只血压正常的眼睛。程序:通过超声生物显微镜(UBM)使用40-MHz探针在有或没有麻醉/镇静的狗中检查ICA的微结构。对SLD或SLD 2 与UBM测量值之间的线性回归分析和相关系数进行了评估;随后,对未经校正和经SLD校正的UBM值进行统计评估。结果:SLD与睫状体裂隙宽度,角凹与巩膜静脉丛之间的最小距离以及巩膜厚度之间存在显着的线性相关性。 SLD 2 与睫状裂隙区域以及巩膜静脉丛区域之间也呈正线性相关。通过在距离上使用SLD或在区域上使用SLD 2 的比率来校正原始UBM测量。尽管犬的体重增加了未经校正的UBM测量值,但经过SLD校正的UBM值仍然相似,在任何一只狗中均无明显统计学差异。结论:SLD校正对比较不同体型/体重的狗的ICA的UBM测量值在临床上将是有用的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号