Background: Portable blood glucose meters (PBGMs) are useful for serial measurements of blood glucose and creation of blood glucose curves in veterinary practice. However, it is necessary to validate PBGMs designed for people for veterinary use. Objectives: Our objective was to evaluate the accuracy of 2 PBGMs designed for people for use in dogs and cats. Methods: The blood glucose levels were determined in blood samples collected from 69 dogs and 26 cats admitted to the Kagoshima University Veterinary Teaching Hospital, using a MEDISAFE [PBGM-T] and an Antsense III [PBGM-H], and a FUJI DRI-CHEM 7000V as reference method. The correlations and agreements among the results were statistically analyzed. Results: Simple regression analyses revealed a high correlation between values from both PBGMs and the reference method in both dogs and cats. However, Passing-Bablok regression and Bland-Altman analyses revealed that the data from both PBGMs did not show statistical agreement with the reference values. Concordance correlated coefficients were moderate for the PBGM-T and almost perfect for the PBGM-H for canine samples, and were poor for the PBGM-T and substantial for the PBGM-H for feline samples. Hematocrit values significantly affected the results of the PBGM-T, but not the PBGM-H. Error grid analyses revealed that all measurements from both PBGMs would lead to acceptable treatment decisions. Conclusions: Our findings suggest that both PBGMs, especially the PBGM-H, would be clinically useful in small animal practice, although there was a bias between each PBGM and the reference method.
机译:背景技术:便携式血糖仪(PBGM)可用于兽医实践中的血糖连续测量和血糖曲线的创建。但是,有必要验证为兽用设计的PBGM。目的:我们的目的是评估为人和狗设计的2种PBGM的准确性。方法:使用MEDISAFE [PBGM-T]和Antsense III [PBGM-H]以及FUJI DRI-FU对鹿儿岛大学兽医教学医院收治的69只狗和26只猫的血样中的血糖水平进行测定。 CHEM 7000V作为参考方法。统计分析结果之间的相关性和一致性。结果:简单的回归分析显示,狗和猫的PBGM值与参考方法之间的相关性很高。但是,Passing-Bablok回归和Bland-Altman分析显示,两个PBGM的数据均未显示出与参考值的统计一致性。对于犬类样品,PBGM-T的一致性相关系数适中,对于PBGM-H而言几乎是完美的,对于PBGM-T,一致性相关系数较差,而对于猫样品,PBGM-H的一致性相关系数较高。血细胞比容值显着影响PBGM-T的结果,但不影响PBGM-H的结果。误差网格分析表明,两个PBGM的所有测量结果都会导致可接受的治疗决策。结论:我们的发现表明,尽管每种PBGM与参考方法之间存在偏差,但两种PBGM,尤其是PBGM-H,在小动物实践中都将在临床上有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号