The comparative biomechanics of the reinforced interdental crossover and the stout loop composite splints for mandibular fracture repair in dogs.

机译:犬齿间交叉强化和粗loop复合夹板用于犬下颌骨骨折修复的比较生物力学。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objectives: To describe a new technique, the reinforced interdental crossover composite splint (RIC), for transverse mandibular fracture repair in dogs. This technique was compared biomechanically with the established reinforced interdental Stout loop composite splint (RIS) technique. Methods: Six pairs of mandibles from young adult small breed dogs were used for the study. Osteotomies were created in a standardized fashion and fixed with either RIC or RIS. All composite splint constructs were tested biomechanically with a cantilever bending force, using a single column testing machine at a rate of 2 mm/min. The time of application, amount of composite used, ultimate force, stiffness, total displacement, and total energy absorbed during displacement of the rostral mandibular segment were calculated and compared between the two groups. Results: No significant difference was found when comparing the time of application of the RIC and the RIS techniques. All implants failed by either composite resin fracture over the region of the osteotomy or by fracture between the first and second molar followed by detachment of the resin from the lingual enamel surface of the first molar. Differences between the RIC and RIS in force (80.5 N+or-40.3 and 51.8 N+or-27.4. respectively) and stiffness (16.2 N/mm+or-4.4 and 10.1 N/mm+or-4.1 respectively) were significant (p=0.03). However differences between the two techniques in displacement and total energy absorbed were not significant. Clinical significance: In experimentally fractured mandibles of young adult dogs there is evidence that RIC is biomechanically similar to RIS.Digital Object Identifier http://dx.doi.org/10.3415/VCOT-12-11-0140
机译:目的:描述一种新技术,即犬齿间交叉复合夹板(RIC),用于犬的下颌骨横向骨折修复。将该技术与已建立的强化齿间Stout环复合夹板(RIS)技术进行了生物力学比较。方法:使用六对成年小型犬的下颌骨进行研究。截骨术以标准化方式创建,并用RIC或RIS固定。使用单柱测试机以2 mm / min的速度用悬臂弯曲力对所有复合夹板结构进行生物力学测试。计算应用时间,复合材料的使用量,极限力,刚度,总位移以及在下颌下颌节位移期间吸收的总能量,并在两组之间进行比较。结果:比较RIC和RIS技术的应用时间没有发现显着差异。所有植入物均由于复合树脂在截骨区域上的断裂或第一和第二磨牙之间的断裂,随后树脂从第一磨牙的舌釉质表面脱离而失败。 RIC和RIS在力(分别为80.5 N +或-40.3和51.8 N +或-27.4)和刚度(分别为16.2 N / mm +或-4.4和10.1 N / mm +或-4.1)之间的差异非常大( p = 0.03)。但是,这两种技术在位移和吸收的总能量之间没有显着差异。临床意义:在成年狗的实验性下颌骨中,有证据表明RIC与RIS的生物力学相似。数字对象标识符http://dx.doi.org/10.3415/VCOT-12-11-0140

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号