首页> 外文期刊>Veterinary and Comparative Orthopaedics and Traumatology >Theoretical discrepancy between cage size and efficient tibial tuberosity advancement in dogs treated for cranial cruciate ligament rupture.
【24h】

Theoretical discrepancy between cage size and efficient tibial tuberosity advancement in dogs treated for cranial cruciate ligament rupture.

机译:治疗颅交叉韧带破裂的犬的笼大小与有效胫骨结节进展之间的理论差异。

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVES: To calculate the difference between the desired tibial tuberosity advancement (TTA) along the tibial plateau axis and the advancement truly achieved in that direction when cage size has been determined using the method of Montavon and colleagues. To measure the effect of this difference on the final patellar tendon-tibial plateau angle (PTA) in relation to the ideal 90. METHODS: Trigonometry was used to calculate the theoretical actual advancement of the tibial tuberosity in a direction parallel to the tibial plateau that would be achieved by the placement of a cage at the level of the tibial tuberosity in the osteotomy plane of the tibial crest. The same principle was used to calculate the size of the cage that would have been required to achieve the desired advancement. The effect of the difference between the desired advancement and the actual advancement achieved on the final PTA was calculated. RESULTS: For a given desired advancement, the greater the tibial plateau angle (TPA), the greater the difference between the desired advancement and the actual advancement achieved. The maximum discrepancy calculated was 5.8 mm for a 12 mm advancement in a case of extreme TPA (59). When the TPA was less than 31, the PTA was in the range of 90 to 95. CLINICAL SIGNIFICANCE: A discrepancy does exist between the desired tibial tuberosity advancement and the actual advancement in a direction parallel to the TPA, when the tibial tuberosity is not translated proximally. Although this has an influence on the final PTA, further studies are warranted to evaluate whether this is clinically significant.
机译:目的:计算使用Montavon及其同事确定的笼尺寸后,沿胫骨平台轴的所需胫骨粗隆度前进(TTA)与在该方向上真正实现的前进之间的差异。为了测量相对于理想90度的差异对最终plate骨腱-胫骨平台高角度(PTA)的影响。方法:使用三角法计算了胫骨结节在平行于胫骨平台的方向上的理论实际进展通过将笼子放置在胫骨rest的截骨平面内的胫骨粗隆的水平上可以实现。使用相同的原理来计算保持笼子的尺寸,以实现所需的推进能力。计算了期望进度和实际进度之间的差异对最终PTA的影响。结果:对于给定的期望进展,胫骨平台稳定角(TPA)越大,期望进展与实际获得的进展之间的差就越大。在极端TPA的情况下,对于前进12毫米,计算得出的最大差异为5.8毫米(59)。当TPA小于31时,PTA在90到95范围内。临床意义:当胫骨结节不存在时,理想的胫骨结节进展与平行于TPA方向的实际进展之间确实存在差异。近端翻译。尽管这会影响最终的PTA,但仍需要进一步研究以评估其是否具有临床意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号