首页> 外文期刊>Turkish Journal of Engineering and Environmental Sciences >Pre-Treatment of Antibiotic Formulation Wastewater by O_3,O_3/H_2O_2,and O_3/UV Processes
【24h】

Pre-Treatment of Antibiotic Formulation Wastewater by O_3,O_3/H_2O_2,and O_3/UV Processes

机译:O_3,O_3 / H_2O_2和O_3 / UV工艺预处理抗生素制剂废水

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The treatment of synthetically prepared antibiotic formulation wastewater with O_3,O_3/H_2O_2,and O_3/UV processes was examined.The efficiencies of the treatment processes were compared by means of COD,absorbance removals,and biodegradability enhancement.The efficiencies of O_3/pH=7,O_3/ pH=12,and O_3/H_2O_2(50 mM)processes were almost identical in terms of COD and UV254 removals.The BOD_3/COD ratio of formulation wastewater increased from 0.02 to 0.38 and 0.5 at the end of 1 hr of ozone treatment at pH=7 and pH=12,respectively.For the formulation wastewater subjected to O_3/UV process at pH=7,parallel to the UV254 removal efficiency,a 20% increase was obtained in the Oxygen Uptake Rate(OUR)value compared to that of mere ozonation.
机译:考察了O_3,O_3 / H_2O_2和O_3 / UV工艺处理合成抗生素制剂废水的效果。通过COD,吸光度的去除和生物降解能力的提高,比较了处理工艺的效率。O_3/ pH = 7,O_3 / pH = 12,和O_3 / H_2O_2(50 mM)过程在COD和UV254去除方面几乎相同。配制废水的BOD_3 / COD比在1小时结束时从0.02增加到0.38和0.5。分别在pH = 7和pH = 12的条件下进行臭氧处理。对于在pH = 7的条件下进行O_3 / UV处理的配方废水,与UV254的去除效率平行,吸氧率(OUR)值提高了20%与单纯的臭氧化相比