Fretting is known to be a major cause of contact deterioration and failure in connector systems. During fretting the contact resistance generally increases slowly with time. Superimposed on this slow increase in contact resistance are rapid changes in contact resistance within fractions of a second, called intermittences or short duration discontinuities. Consideration is given to the evaluation of surface wear during the fretting process using a 3D laser scanner. The surface wear of both plated and solid surfaces are related to the frequency of the intermittency events. High speed measurements of contact voltage drop and contact current have been carried out and the results are evaluated using general contact theory. It is shown that sudden changes in contact resistance can be caused by the interaction of surface films and metallic contact combined with the melting of current carrying asperities. The latter phenomena also accounting for volt drops across the contact interface which exceed the melting voltage of the material.
机译:众所周知,微动磨损是连接器系统中触点劣化和故障的主要原因。在微动期间,接触电阻通常会随时间缓慢增加。接触电阻的这种缓慢增加叠加在几分之一秒之内的接触电阻快速变化(称为间歇或短时间断)。考虑使用3D激光扫描仪评估微动过程中的表面磨损。电镀和实心表面的磨损都与间歇事件的发生频率有关。进行了接触电压降和接触电流的高速测量,并使用通用接触理论对结果进行了评估。结果表明,接触电阻的突然变化可能是由于表面膜和金属接触的相互作用以及载流子的熔化而引起的。后一种现象还解释了跨接触界面的电压降超过了材料的熔化电压。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号