...
首页> 外文期刊>Transfusion: The Journal of the American Association of Blood Banks >Evaluation of the quality of blood components obtained after automated separation of whole blood by a new multiunit processor
【24h】

Evaluation of the quality of blood components obtained after automated separation of whole blood by a new multiunit processor

机译:新型多单元处理器自动分离全血后获得的血液成分质量的评估

获取原文
获取原文并翻译 | 示例

摘要

Background The Reveos system (Terumo BCT) is a fully automated device able to process four whole blood (WB) units simultaneously into a plasma unit, a red blood cell (RBC) unit, and an interim platelet (PLT) unit (IPU). Multiple IPUs can be pooled to form a transfusable PLT product. The aim of our study was to evaluate the quality of components made with the Reveos system from either fresh (2-8 hr) or overnight-held WB. Study Design and Methods A prototype of the Reveos system was used to process WB. RBCs were resuspended in SAGM, leukoreduced, and assayed for in vitro quality variables during a 42-day storage period at 2 to 6°C. Twenty-four-hour in vivo recovery was determined on Day 42. Plasma was assayed for cellular contamination and activation variables. IPUs were pooled with SSP+ additive solution for in vitro quality assessments during a 7-day storage period at room temperature. Results Reveos-produced RBCs and plasma units met the predefined requirements. RBC recovery was superior to control units. On Day 42, hemolysis was below 0.8% and in vivo recovery was above 75% for all RBCs. Cellular contamination was lower for Reveos-produced plasma. PLT yield was higher with overnight-stored WB. PLT quality was well maintained during storage with no significant differences between the two groups. Conclusion Blood components prepared with the Reveos from fresh or overnight-held WB meet quality criteria without any relevant difference between the two groups. The Reveos system has the potential to increase efficacy and standardization of blood component preparation.
机译:背景Reveos系统(Terumo BCT)是一种全自动设备,能够将四个全血(WB)单元同时处理为血浆单元,红血球(RBC)单元和临时血小板(PLT)单元(IPU)。可以将多个IPU合并以形成可转换的PLT产品。我们研究的目的是评估由Reveos系统制成的新鲜(2-8小时)或隔夜保持的WB组件的质量。研究设计和方法Reveos系统的原型用于处理WB。将RBC重悬于SAGM中,进行白细胞减少,并在2至6°C下42天的储存期中分析体外质量变量。在第42天测定24小时体内恢复。测定血浆中的细胞污染和激活变量。将IPU与SSP +添加剂溶液合并,在室温下7天的存储期内进行体外质量评估。结果Reveos生产的RBC和血浆装置达到了预定要求。红细胞回收率优于对照组。在第42天,所有RBC的溶血均低于0.8%,体内回收率高于75%。对于Reveos生产的血浆,细胞污染较低。隔夜存放的WB的PLT产量较高。在储存过程中,PLT质量保持良好,两组之间无显着差异。结论用Reveos从新鲜或过夜保存的WB制备的血液成分符合质量标准,两组之间没有任何相关差异。 Reveos系统具有提高功效和血液成分制备标准化的潜力。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号