...
首页> 外文期刊>Transfusion: The Journal of the American Association of Blood Banks >Evaluation of the automated collection and extended storage of apheresis platelets in additive solution
【24h】

Evaluation of the automated collection and extended storage of apheresis platelets in additive solution

机译:评估单采血小板在添加剂溶液中的自动收集和扩展存储

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BACKGROUND: Collecting apheresis platelets (PLTs) into additive solution has many potential benefits. The new Trima software (Version 6.0, CaridianBCT) allows automated addition of PLT additive solution (PAS) after collection, compared to Trima Version 5.1, which only collects PLTs into plasma. The aim of this study was to compare PLT quality during extended storage, after collection with the different Trima systems. STUDY DESIGN AND METHODS: Apheresis PLTs were collected using both Trima Accel apheresis systems. The test PLT units (n = 12) were collected using the new Trima Version 6.0 into PLT AS (PAS-IIIM), while the control units (n = 8) were collected into autologous plasma using Trima Version 5.1. All units were stored for 9 days, and in vitro cell quality variables were evaluated during this time. RESULTS: PLTs collected in PAS-IIIM maintained a stable pH between 7.2 and 7.4, whereas plasma-stored apheresis units exhibited significantly increased acidity during storage, due to lactate accumulation and bicarbonate exhaustion. Plasma-stored PLTs also demonstrated a more rapid consumption of glucose. However, there was little difference in PLT activation or cytokine secretion between PAS-IIIM and control PLTs. CONCLUSION: These data indicate that apheresis PLT concentrates collected in PAS-IIIM, using Trima Version 6.0 software, maintained acceptable PLT metabolic and cellular characteristics until Day 9 of storage.
机译:背景:将单采单采血小板(PLT)收集到添加剂溶液中具有许多潜在的好处。与仅将PLT收集到血浆中的Trima版本5.1相比,新的Trima软件(版本6.0,CaridianBCT)允许在收集后自动添加PLT添加剂溶液(PAS)。这项研究的目的是在收集不同的Trima系统后,比较长期储存期间的PLT质量。研究设计和方法:使用Trima Accel单采血液分离术系统收集无创PLT。使用新的Trima版本6.0将测试的PLT单元(n = 12)收集到PLT AS(PAS-IIIM)中,而使用Trima版本5.1将对照单元(n = 8)收集到自体血浆中。所有单位均保存9天,并在此期间评估体外细胞质量变量。结果:PAS-IIIM中收集的PLT的pH值保持在7.2至7.4之间,而血浆存储的单采血液分离设备在存储过程中由于乳酸的积累和碳酸氢根的消耗而酸度显着增加。血浆储存的PLTs还显示出葡萄糖消耗更快。但是,PAS-IIIM与对照PLT之间的PLT活化或细胞因子分泌几乎没有差异。结论:这些数据表明,使用Trima Version 6.0软件在PAS-IIIM中收集的单采血液分离术浓缩物在储存的第9天之前保持可接受的PLT代谢和细胞特征。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号