首页> 外文期刊>Transfusion: The Journal of the American Association of Blood Banks >Function of platelets in apheresis platelet concentrates and in patient blood after transfusion as assessed by Impact-R.
【24h】

Function of platelets in apheresis platelet concentrates and in patient blood after transfusion as assessed by Impact-R.

机译:根据Impact-R评估,血小板在单采单采血小板浓缩物中和输血后患者血液中的功能。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BACKGROUND: Platelet (PLT) transfusion is a mainstream therapy for preventing or treating bleeding episodes in patients with thrombocytopenia. The efficacy is usually estimated from the corrected count increment of PLTs after transfusion, which does not assess PLT function. We therefore evaluated PLT function in blood samples of patients with thrombocytopenia before and after transfusion. STUDY DESIGN AND METHODS: PLT function was assessed in 24 chemotherapy-treated patients and in the PLT concentrates (PCs) by the Impact-R (DiaMed). This device evaluates PLT adhesion and aggregation recorded as surface coverage (%) and size of aggregates (AS microm(2)). P-selectin expression was determined by flow cytometry. RESULTS: The PCs were stored for a median of 70 hours before transfusion. An analysis stratified by the median storage of PCs (<70 hr or >70 hr) showed no differences in the SC, the AS, and P-selectin expression between these concentrates' groups. Transfusion resulted in an increase of adhering PLTs in the patients after transfusion. There were no differences in the AS and in P-selectin expression before and after transfusion, but the AS increased after transfusion upon ex vivo exposure to adenosine 5'-diphosphate. P-selectin expression was significantly lower in the patient group receiving PCs stored for more than 70 hours. CONCLUSION: The current trial shows the feasibility of using the Impact-R to assess the function of transfused PLTs in the patient's blood stream.
机译:背景:血小板输注是预防或治疗血小板减少症患者出血事件的主流疗法。通常根据输血后校正后的PLT计数增加来评估疗效,而PLT的计数增量不能评估PLT功能。因此,我们评估了输血前后血小板减少症患者血液样本中的PLT功能。研究设计和方法:通过Impact-R(DiaMed)对24例接受化疗的患者和PLT浓缩物(PC)的PLT功能进行了评估。此设备评估记录为表面覆盖率(%)和聚集体大小(AS microm(2))的PLT粘附和聚集。通过流式细胞术确定P-选择蛋白表达。结果:输血前将PC储存了70个小时。根据PC的中位储存量(<70 hr或> 70 hr)进行的分层分析显示,这些浓缩物组之间的SC,AS和P-选择蛋白表达没有差异。输血导致患者输血后粘附的PLT增加。输血前后AS和P-选择蛋白表达没有差异,但是在离体暴露于腺苷5'-二磷酸时输血后AS增加。在接受保存超过70小时的PC的患者组中,P-选择素的表达明显较低。结论:本试验显示了使用Impact-R评估患者血液中输注PLT的功能的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号