首页> 外文期刊>Transfusion: The Journal of the American Association of Blood Banks >Identification and quantification of fetal red blood cells in maternal blood by a dual-color flow cytometric method: evaluation of the Fetal Cell Count kit.
【24h】

Identification and quantification of fetal red blood cells in maternal blood by a dual-color flow cytometric method: evaluation of the Fetal Cell Count kit.

机译:通过双色流式细胞术鉴定和定量母体血液中的胎儿红细胞:评估胎儿细胞计数试剂盒。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: As an alternative to the cumbersome Kleihauer-Betke test (KBT), flow cytometry represents a powerful method for the identification and quantification of fetal red blood cells (RBCs) in maternal circulation. STUDY DESIGN AND METHODS: The aim of this study was to evaluate the Fetal Cell Count kit (IQ Products), an innovative flow cytometric method, based on the combination of antibodies directed, respectively, against fetal hemoglobin (HbF) and carbonic anhydrase (CA), a marker expressed after birth, to discriminate fetal RBCs from adult F cells containing HbF. The investigation was performed by two French laboratories that compared the data obtained by flow cytometry and KBT in 455 pregnant or just-delivered women as well as in 124 artificial mixtures containing from 0.01 to 5.00 percent cord cells. RESULTS: The FL1/FL2 histogram allowed distinction between fetal RBCs (HbF+, CA-), F cells (HbF+, CA+), and adult RBCs (HbF-, CA+). The limits of detection and quantification were determined at 0.03 and 0.10 percent or 0.02 and 0.05 percent when analyzing 100,000 or 200,000 events, respectively. Linearity was demonstrated between 0.01 and 5.00 percent fetal cells in the mixtures (r = 0.95, p < 0.01). A good correlation between fluorescence-activated cell sorting (FACS) and KBT results was obtained with artificial mixtures (r = 0.94, p < 0.01). From the 405 Kleihauer-negative samples, none were identified as positive by FACS. Among the 50 Kleihauer-positive samples, 6 were shown not to contain fetal cells but F cells by FACS. CONCLUSION: With this new dual-color flow cytometric method, accurate evaluation of fetomaternal hemorrhage was achieved even in the face of HbF of maternal origin.
机译:背景:作为繁琐的Kleihauer-Betke检验(KBT)的替代方法,流式细胞术是鉴定和定量母体循环中胎儿红细胞(RBC)的有力方法。研究设计和方法:这项研究的目的是评估胎儿细胞计数试剂盒(IQ产品),这是一种创新的流式细胞术方法,基于分别针对胎儿血红蛋白(HbF)和碳酸酐酶(CA)的抗体组合)(一种在出生后表达的标记),用于将胎儿红细胞与含有HbF的成年F细胞区分开来。这项调查是由两个法国实验室进行的,他们对455名孕妇或刚分娩的妇女以及124种含有0.01%至5.00%脐带细胞的人工混合物中的流式细胞仪和KBT数据进行了比较。结果:FL1 / FL2直方图可以区分胎儿RBC(HbF +,CA-),F细胞(HbF +,CA +)和成年RBC(HbF-,CA +)。当分析100,000个或200,000个事件时,检出限和定量限分别为0.03%和0.10%或0.02%和0.05%。混合物中胎儿细胞的线性介于0.01%和5.00%之间(r = 0.95,p <0.01)。使用人工混合液,荧光激活细胞分选(FACS)和KBT结果之间具有良好的相关性(r = 0.94,p <0.01)。从405个Kleihauer阴性样品中,FACS均未鉴定出阳性。在50个Kleihauer阳性样品中,有6个通过FACS显示不含胎儿细胞,但含有F细胞。结论:通过这种新的双色流式细胞术方法,即使面对母源血型HbF,也能准确评估母源性出血。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号