首页> 外文期刊>Transfusion: The Journal of the American Association of Blood Banks >Evaluation of a new generation of culture bottle using an automated bacterial culture system for detecting nine common contaminating organisms found in platelet components.
【24h】

Evaluation of a new generation of culture bottle using an automated bacterial culture system for detecting nine common contaminating organisms found in platelet components.

机译:使用自动细菌培养系统对新一代培养瓶进行评估,以检测血小板成分中发现的九种常见污染生物。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

BACKGROUND: An automated bacterial culture system (BacT/ALERT 3D, bioMerieux) has been previously validated with a variety of bacteria in platelets. The recovery of bacteria in platelets using a new generation of culture bottles that do not require venting and that use a liquid emulsion sensor was studied. STUDY DESIGN AND METHODS: Bacillus cereus, Enterobacter cloacae, Escherichia coli, Klebsiella oxytoca, Staphylococcus aureus, Staphylococcus epidermidis, Serratia marcescens, Streptococcus viridans, and Propionibacterium acnes isolates were inoculated into Day 2 platelets to concentrations of 10 and 100 CFU per mL. Samples were then studied with current and new aerobic, anaerobic, and pediatric bottles. RESULTS: All organisms, except P. acnes, were detected in a mean time of 9.2 to 20.4 (10 CFU/mL) or 8.7 to 18.6 (100 CFU/mL) hours. P. acnes was detected in a mean time of 69.2 (10 CFU/mL) or 66.0 (100 CFU/mL) hours. The 10-fold increase in inoculum was associated with a mean 9.2 percent difference in detection time. The aerobic, anaerobic, and pediatric bottles had a mean difference in detection time (hours) between the current and new bottles of 0.10 (p=0.61), 0.4 (p=0.38), and 1.0 (p < 0.001), respectively. CONCLUSION: No difference in detection time between the current and new aerobic and anaerobic bottles was demonstrated. The new pediatric bottles had a small but significant delay in detection.
机译:背景:自动化细菌培养系统(BacT / ALERT 3D,bioMerieux)先前已通过血小板中的多种细菌进行了验证。研究了使用不需要排气且使用液体乳状液传感器的新一代培养瓶回收血小板中细菌的方法。研究设计和方法:将蜡状芽孢杆菌,阴沟肠杆菌,大肠杆菌,产酸克雷伯菌,金黄色葡萄球菌,表皮葡萄球菌,粘质沙雷氏菌,绿色链球菌和痤疮丙酸杆菌分离株接种到每毫升10毫升的第2天血小板中,以10 FU的浓度接种至C浓度为100FU。然后使用当前和新的需氧,厌氧和小儿瓶研究样品。结果:除痤疮丙酸杆菌外,所有生物的平均时间为9.2至20.4(10 CFU / mL)或8.7至18.6(100 CFU / mL)小时。痤疮丙酸杆菌的平均时间为69.2(10 CFU / mL)或66.0(100 CFU / mL)小时。接种量增加10倍与检测时间平均差异9.2%有关。有氧,无氧和小儿瓶的检测时间(小时)在当前瓶和新瓶之间的平均差分别为0.10(p = 0.61),0.4(p = 0.38)和1.0(p <0.001)。结论:目前和新的需氧和厌氧瓶之间的检测时间没有差异。新的儿科奶瓶的检测延迟很小但很明显。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号