首页> 外文期刊>Transfusion: The Journal of the American Association of Blood Banks >A new automated cell washer device for thawed cord blood units.
【24h】

A new automated cell washer device for thawed cord blood units.

机译:一种用于融化脐带血单元的新型自动细胞清洗器。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The current available techniques to wash out DMSO from thawed umbilical cord blood (UCB) units are based essentially on standard centrifugation in an open system with various degrees of cell loss. STUDY DESIGN AND METHODS: We evaluated the capacity of a new automated closed device (Cytomate, Baxter, IL) to wash out the DMSO from thawed UCB units, saving at the same time the progenitor and accessory cells in terms of CD34+ cells and MNCs. We modified the standard software of the device and calculated the cell recovery on 25 UCB units. Moreover, we set up a new gas chromatographic method to exactly detect the DMSO removal rate. RESULTS: To evaluate the efficiency of the Cytomate device, we considered the postthawing (prewashing) versus postwashing cell recovery. The average recovery (%) in terms of total nucleated cells was 63.30 (range, 40.12-89.00), CD34+ cells was 70.20 (range, 11.51-89.01), CD3+ cells was 61.01 (range, 28.80-87.08), CD4+ cells was 62.53 (range, 30.62-96.73), CD8+ cells was 57.4 (range, 26.87-94.72), CD19+ cells was 63.33 (range, 39.10-90.33), CD16+/56+ cells was 70.67 (range, 8.91-98.40), CFU-GM was 74.33 (range, 20.23-98.60), total CFUs was 82.34 (range, 14.83-247.12), and viability was 89.67(range, 70.74-98.30). The total working time required was, on average, 15 minutes (range, 7-20). CONCLUSIONS: The Cytomate device demonstrated a satisfying efficiency in cell recovery and in maintaining the clonogenic power of the UCB graft. The removal rate of DMSO was practically complete with evident advantages for the recipient. Finally, the entire manipulation performed in a closed system revealed to be safe, maintaining the sterility of the graft.
机译:背景:目前从融化的脐带血(UCB)单元中洗出DMSO的现有技术基本上是基于开放系统中具有不同程度细胞损失的标准离心。研究设计和方法:我们评估了新型自动封闭设备(Cytomate,Baxter,IL)从融化的UCB装置中冲洗DMSO的能力,同时节省了CD34 +细胞和MNC的祖细胞和辅助细胞。我们修改了设备的标准软件,并计算了25个UCB单元的电池回收率。此外,我们建立了一种新的气相色谱方法以准确检测DMSO去除率。结果:为了评估Cytomate装置的效率,我们考虑了融化后(预洗涤)与洗涤后细胞回收率的关系。总有核细胞的平均回收率(%)为63.30(范围40.12-89.00),CD34 +细胞为70.20(范围11.51-89.01),CD3 +细胞为61.01(范围28.80-87.08),CD4 +细胞为62.53 (范围30.62-96.73),CD8 +细胞为57.4(范围26.87-94.72),CD19 +细胞为63.33(范围39.10-90.33),CD16 + / 56 +细胞为70.67(范围8.91-98.40),CFU-GM为74.33(范围20.23-98.60),总CFU为82.34(范围14.83-247.12)和生存力为89.67(范围70.74-98.30)。平均所需的总工作时间为15分钟(范围7-20)。结论:Cytomate装置在细胞恢复和维持UCB移植物的克隆能力方面显示出令人满意的效率。 DMSO的去除率实际上是完整的,对接收者而言具有明显的优势。最后,在封闭系统中进行的整个操作显示出安全性,可保持移植物的无菌性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号