BACKGROUND: A formal quality assurance (QA) scheme has been established to facilitate proficiency testing for granulocyte antibodies and antigens. STUDY DESIGN AND METHODS: Fifteen laboratories participated in the Fourth International Granulocyte Immunology Workshop. The main objective of the workshop was to establish a formal QA scheme for granu- locyte serology and molecular typing methods. A secondary objective was to determine the relative sensitivities of the granulocyte immunofluorescence test, granulocyte agglutination test, and MoAb immobilization assays using defined antisera and protocols. RESULTS: Laboratories scored between 16.7 and 100 percent (mean, 57.5%) of the maximum available in the serologic part of this QA exercise. There were particular problems in detecting granulocyte-specific human neutrophil antigen-1 (HNA-1a) IgM antibodies and HNA-2a antibodies in the presence of HNA-1b antibodies. The granulocyte immunofluorescence test was more sensitive than the granulocyte agglutination test in titration studies, but the latter method more readily identified the presence of HNA-3a antibodies. HNA genotyping was generally well performed, with nine laboratories obtaining 100-percent correct results for HNA-1a, HNA-1b, and HNA-1c. CONCLUSIONS: There is a need to standardize the detection of granulocyte-specific antibodies. Laboratories with good performance tended to use two methods for detecting granulocyte-specific antibodies and an HNA-typed panel of granulocytes. The use of a method for elucidating mixtures of granulocyte- and lymphocyte-reactive antibodies (e.g., MoAb immobilization assay) and the use of methods for detecting both cytotoxic and noncytotoxic HLA class I antibodies were also associated with a higher than average performance.
机译:背景:已经建立了正式的质量保证(QA)计划,以促进粒细胞抗体和抗原的能力测试。研究设计和方法:十五个实验室参加了第四届国际粒细胞免疫学研讨会。研讨会的主要目的是为粒细胞血清学和分子分型方法建立一个正式的质量保证体系。第二个目标是使用定义的抗血清和方案确定粒细胞免疫荧光测试,粒细胞凝集测试和MoAb固定化测定的相对敏感性。结果:实验室在此QA练习的血清学部分中获得的最高评分为16.7%至100%(平均57.5%)。在存在HNA-1b抗体的情况下,检测粒细胞特异性人类嗜中性粒细胞抗原1(HNA-1a)IgM抗体和HNA-2a抗体存在特殊问题。在滴定研究中,粒细胞免疫荧光测试比粒细胞凝集测试更敏感,但是后一种方法更容易确定HNA-3a抗体的存在。 HNA基因分型通常表现良好,有9个实验室获得HNA-1a,HNA-1b和HNA-1c的100%正确结果。结论:有必要标准化粒细胞特异性抗体的检测。性能良好的实验室倾向于使用两种检测粒细胞特异性抗体的方法和一种HNA型粒细胞。阐明粒细胞和淋巴细胞反应性抗体混合物的方法的使用(例如MoAb固定化测定)以及检测细胞毒性和非细胞毒性HLA I类抗体的方法的使用还具有高于平均水平的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号