Objective: To evaluate efficiency and performance of Erytra? analyser in comparison to the reference platform of the NBT immunohaematology laboratory (Bio-Rad ID-System). Background: Moving to automation or semi-automation is a major focus of transfusion centres. The Erytra? (Grifols) is a new fully automated walk-away analyser with high volume processing capacity for pre-transfusion testing, designed to be used with the unique 8-column DG Gel? cards. Study Design and Methods: A total of 2201 immunohaematological tests (1041 ABO/D grouping, 1041 antibody screening, 51 antibody identification, 45 newborns (ABO/D and DAT) and 23 crossmatches were performed on 1160 donor/patient whole blood samples. Erytra?'s performance was assessed by means of a stress test replicating the routine work of a hospital laboratory. Results: Concordant results between the Erytra? and the reference method were obtained in 2195 (99·73 %) of the tests. There were only three discrepancies out of 6246 reactions (0·05%) in ABO/D grouping, all in the reverse group which did not mislead to group identification. Of the 1041 samples screened for antibody presence, Erytra? detected all the relevant antibodies [9 not detected weak prophylactic anti-D were determined to be clinically nonsignificant (0·1 IUmL-1)] while Bio-Rad ID-System missed one anti-e and one anti-Jka. Concordance for D grouping, crossmatching and newborns was 100%. Results of the simulated stress test exercise highlighted the capacity of Erytra? for absorbing into 4h workloads equivalent to 24h of routine. Conclusions: Grifols' Erytra? analyser showed reliable high sensitivity, velocity and capacity to cope with high workload in the immunohaematology laboratory routine.
机译:目的:评估Erytra的效率和性能?分析仪与NBT免疫血液学实验室(Bio-Rad ID-System)的参考平台相比。背景:转向自动化或半自动化是输血中心的主要重点。 Erytra? (Grifols)是一款新型的全自动走检分析仪,具有高容量处理能力,可用于输血前测试,旨在与独特的8柱DG Gel?一起使用。牌。研究设计和方法:对1160个供体/患者全血样本进行了总共2201次免疫血液学测试(1041 ABO / D分组,1041抗体筛选,51抗体鉴定,45个新生儿(ABO / D和DAT)和23个交叉匹配)。结果通过在2195次(99·73%)的测试中获得了Erytra?和参考方法之间的一致结果,仅通过重复测试医院实验室的日常工作来评估?的性能。在ABO / D分组的6246个反应中有3个差异(0·05%),全部在反向组中,不会误导组识别。在1041个筛查抗体存在的样品中,Erytra?检测到了所有相关抗体[9检测到的弱预防性D的临床意义不显着(<0·1 IUmL-1),而Bio-Rad ID-System错过了1个抗e和1个Jka,D分组,交叉匹配和新生儿的一致性为100 %。模拟应力的结果测试练习突出了Erytra的能力?吸收相当于4小时例行工作的4小时工作量。结论:Grifols的Erytra?分析仪在免疫血液学实验室常规中显示出可靠的高灵敏度,高速度和应对高工作量的能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号