首页> 外文期刊>Transactions of the American Ophthalmological Society. >The use of computerized videokeratography as an aid in fitting rigid gas permeable contact lenses.
【24h】

The use of computerized videokeratography as an aid in fitting rigid gas permeable contact lenses.

机译:使用计算机视频角膜造影术来辅助安装刚性透气性隐形眼镜。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: To assess the efficacy of computerized corneal topography in (1) fitting cosmetic rigid gas permeable contact lenses on normal corneas and (2) patients who have keratoconus. METHODS: In study 1, 26 patients were fitted with cosmetic contact lenses. In 13 patients, the first rigid gas permeable lens was chosen on the basis of corneal topography using the EyeSys videokeratoscope and contact lens software version 2.11w. Thirteen control patients were fitted with rigid gas permeable contact lenses by means of diagnostic contact lenses. The number of parameter changes required in each group to reach the best fit were compared. In study 2, the records of 28 patients (41 eyes) with keratoconus who had been successfully fit with rigid gas permeable lenses were reviewed. Topographic analysis using the EyeSys videokeratoscope was conducted. The following 8 data points were analyzed: maximum dioptric curvature with respect to the central visual axis, the power at the visual axis (VK), the average keratometry readings within the 3-mm zone, the average flat K at 3-mm central and 5-mm paracentral regions, and the K reading at 1.5, 2.0, and 2.5 mm superior to the visual axis. RESULTS: Study 1: In 10 eyes (38%) fitted with cosmetic contact lenses utilizing corneal topography and the EyeSys contact lens program, the first lens chosen by the computer program was correct with no additional changes in lens parameters required. In the other 16 eyes, 21 parameter changes were required. In the control group, 14 eyes (53%) required no additional change in parameters from the original contact lens that was fitted using diagnostic lenses. In the other 12 eyes, 12 parameter changes were required. Study 2: In the keratoconus group, of the 9 measurements analyzed, the final base curve of patients' rigid gas permeable lenses was correlated most closely with the average flat corneal curvature at the 3-mm central zone. CONCLUSION: Study 1: In fitting cosmetic rigid gas permeable contact lenses, the videokeratoscope with the EyeSys software 2.11w contact lens program proved to be inferior to diagnostic lenses in selecting the final correct contact lens parameters. However, it may be useful in selecting an initial diagnostic lens with which to begin rigid gas permeable fitting. Study 2: In patients with irregular corneas such as keratoconus, corneal topography is helpful in determining the initial base curve of the contact lens. In patients with keratoconus, it appears to be the average flat corneal curvature at the 3.0-mm zone.
机译:目的:评估计算机角膜地形图在(1)在正常角膜和(2)圆锥角膜患者上安装化妆品硬质透气性隐形眼镜的功效。方法:在研究1中,有26例患者装有美容隐形眼镜。在13例患者中,使用EyeSys视频角膜镜和版本2.11w的隐形眼镜,根据角膜地形图选择了首个刚性透气镜。 13名对照患者通过诊断性隐形眼镜安装了刚性透气性隐形眼镜。比较了每组中达到最佳拟合所需的参数更改次数。在研究2中,回顾了28例成功戴上硬性透气性晶状体的圆锥角膜患者(41眼)的记录。使用EyeSys角膜镜进行了地形分析。分析了以下8个数据点:相对于中央视轴的最大屈光度,视轴的屈光力(VK),3毫米区域内的平均角膜曲率法读数,3毫米中心的平均平面K和中心旁5毫米区域,K读数比视轴高1.5、2.0和2.5毫米。结果:研究1:在10眼(38%)的角膜地形图和EyeSys角膜接触镜程序上装有美容隐形眼镜的情况下,计算机程序选择的第一个透镜是正确的,不需要对透镜参数进行任何其他更改。在另外16只眼中,需要更改21个参数。对照组中,有14只眼睛(53%)不需要使用诊断眼镜所配戴的原始隐形眼镜来进一步改变参数。在另外12只眼睛中,需要12个参数更改。研究2:在圆锥角膜组中,分析的9个测量结果中,患者的硬质透气性晶状体的最终基础曲线与3毫米中心区域的平均角膜曲率最密切相关。结论:研究1:在安装化妆品硬质透气隐形眼镜时,带有EyeSys软件2.11w隐形眼镜程序的视频角膜镜在选择最终正确的隐形眼镜参数方面不如诊断眼镜。但是,在选择初始诊断透镜以开始进行刚性透气性装配时可能很有用。研究2:在患有不规则角膜(例如圆锥角膜)的患者中,角膜地形图有助于确定隐形眼镜的初始基础曲线。在圆锥角膜患者中,它似乎是3.0毫米区域的平均平角膜曲率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号