Wall loads were measured in a corrugated-wall model grain bin 2.44 m in diameter and 7.3 m high filled with wheat to a HID ratio equal to 2.0. The model bin was filled either centrally or eccentrically through a chute located along a radial line, coinciding with one of the major axis of the bin, at eccentricity ratios of 0, 0.5, or 0.75. The eccentricity ratio (ER) is defined as the ratio of the distance from the center of the bin to either the filling location or the discharge gate divided by the radius of the bin. The model bin was unloaded either centrally or eccentrically through discharge gates located at ERs of 0, +/-0.5, or +/-0.7. For both an ER of 0.5 and 0.7, two different eccentric discharge gates were used, located on opposite (plus or minus) sides of the bin on a major axis that was parallel to the filling axis. For experiments involving centric filling followed by eccentric unloading, a maximum wall moment of 11.2 kN-m was measured. For experiments involving eccentric filling followed by eccentric unloading, the mutual location of the filling and discharge gates either magnified or reduced the variation in stress within the bin and the resulting moment carried by the walls. For experiments in which the location of both the filling and discharge gates were on the same side of bin, a maximum wall moment of 17.5 kN-m was measured. For tests in which the filling chute was located on the opposite side of the bin from the discharge gate, a maximum wall moment of 3.2 kN-m was measured.
机译:在直径为2.44 m,高度为7.3 m的装有小麦的HID比等于2.0的波纹壁模型谷物仓中测量壁负载。通过沿径向线设置的斜道(与分选箱的主轴之一重合),以偏心比为0、0.5或0.75的方式将模型分箱填充到中心或偏心。偏心率(ER)定义为从料仓中心到填充位置或排放门的距离除以料仓半径的比值。通过位于ER为0,+ /-0.5或+/- 0.7的卸料门在中心或偏心位置上卸下模型仓。对于ER为0.5和0.7的情况,使用了两个不同的偏心卸料门,它们位于料箱的相对(正或负)侧,长轴平行于填充轴。对于涉及中心填充和偏心卸载的实验,测得的最大壁弯矩为11.2 kN-m。对于涉及偏心填充然后再进行偏心卸载的实验,填充和卸料门的相互位置会放大或减小料仓内应力的变化以及壁所产生的力矩。对于装料口和卸料口都位于料箱同一侧的实验,测得的最大壁矩为17.5 kN-m。对于其中装料斜槽位于垃圾箱与卸料门相对的一侧的测试,测得的最大壁矩为3.2 kN-m。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号