Hydrogen sulfide (H2S) concentration and emission at a modern mechanically ventilated swine finishing building with a deep pit were continuously measured for three summer months. Ventilation rates, temperatures, and pig inventory in the building were also continuously measured or recorded. A total of 88 d of valid data were obtained between 26 June and 25 September during which the average daily mean (ADM) ambient temperature was 21.8 degreesC. The test began with 887, 19-kg pigs in the building and ended with 874, 83-kg pigs. Hydrogen sulfide was measured with a sulfur dioxide (SO2) analyzer equipped with a thermal oxidizer that converted H2S to SO2. Building ventilation rates were determined by, continuously monitoring exhaust fan operation and differential static pressure. Daily mean building H2S concentrations ranged from 38 to 536 ppb. The ADM building concentration (average of three locations) was 173 +/- 21 ppb (mean +/- 95% confidence interval). The maximum concentration, averaged over 7- or 12-min sampling periods, was 1,624 ppb. The 25(th), 50(th) (median), and 75(th) percentile values were 413, 527, and 662 g/d for daily mean building H2S emission and 4.4, 5.8, and 12.4 g d(-1) AU(-1) (animal unit = 500 kg live mass present in the building)for daily mean specific emission, respectively. These H2S emissions were much greater than emissions measured or estimated in previous studies. Based on daily means, H2S concentration was inversely proportional (P < 0.05) to ventilation rate (r = -0.68), whereas building H2S emission was influenced somewhat (P < 0.05) by building temperature (r = 0.29) and ventilation rate (r = 0.23).
机译:在夏季的三个月中,连续测量了现代化机械通风的猪场深坑中硫化氢(H2S)的浓度和排放。建筑物中的通风率,温度和生猪存量也得到连续测量或记录。在6月26日至9月25日期间,总共获得了88 d有效数据,其间的平均日平均(ADM)环境温度为21.8摄氏度。该测试从建筑物中的887头19公斤猪开始,到874头83公斤猪结束。硫化氢用配备有将H2S转化为SO2的热氧化剂的二氧化硫(SO2)分析仪进行测量。建筑物通风率的确定是通过持续监控排气扇的运行和静压差来实现的。日均建筑H2S浓度范围为38至536 ppb。 ADM建筑物浓度(三个位置的平均值)为173 +/- 21 ppb(平均+/- 95%置信区间)。在7分钟或12分钟的采样期间内平均得出的最大浓度为1,624 ppb。第25(th),第50(th)(中位数)和75(th)百分位数分别为每天平均建筑H2S排放量413、527和662 g / d,以及4.4、5.8和12.4 gd(-1)AU (-1)(动物单位=建筑中存在的500千克活重)分别用于每日平均比排放。这些H2S排放量远大于先前研究中测量或估算的排放量。根据日常平均值,H2S浓度与通风率成反比(P <0.05)(r = -0.68),而建筑物H2S排放受建筑物温度(r = 0.29)和通风率(r =多少)(P <0.05)影响。 = 0.23)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号