We developed a new optical device (Nikkiso) to assess changes through blood volume monitoring (BVM) during hemodialysis and were able to determine the ideal levels in which changes in blood volume percentage (BV%) occur among hemodialysis patients in one hemodialysis center. We evaluated both the reliability of BVM and these ideal levels in a multicenter group. The purpose of this manuscript is to develop a navigating system to set dry weight in a variety of situations as the final goal. First, based on the obtained BVM (BV%(BVM) ) measurements, the relationships between BV% and hematocrit (BV%(HT) ) and between BV% and CRIT-LINE (BV%(CLM) ; Hema Metrics, Kaysville, UT, USA) were then evaluated. In 30 hemodialysis patients, there was a close correlation between both BV%(BVM) vs. BV%(HT) and BV%(BVM) vs. BV%(CLM) (n=30, r=0.967, P<0.001, and n=36, r=0.7867, P<0.001, respectively). Second, BV% data were obtained from 464 treatment cases performed on 26 subjects in one satellite hemodialysis center on patients whose body weight was deemed clinically suitable. The formulas for the levels of BV% (standardized by the percent change in body weight at the end of hemodialysis treatment: BW%end) were determined. Finally, we revalidated the reliability of the above levels. A total of 1126 measurements were performed on 201 patients whose body weights were deemed suitable in seven hemodialysis centers. New ideal levels were then recalculated. We therefore conclude that BVM is a sufficiently accurate method of monitoring BV% in hemodialysis treatment. Most well-controlled hemodialysis patients display the same pattern of BV%/BW%end. Monitoring BV% during hemodialysis is beneficial for determining dry weight (DW).
机译:我们开发了一种新的光学设备(Nikkiso),以通过血液透析期间的血容量监测(BVM)评估变化,并能够确定一个血液透析中心的血液透析患者中​​血容量百分比(BV%)变化发生的理想水平。我们在多中心小组中评估了BVM的可靠性和这些理想水平。该手稿的目的是开发一种导航系统,以将各种情况下的干重设置为最终目标。首先,根据获得的BVM(BV%(BVM))测量值,BV%与血细胞比容(BV%(HT))之间以及BV%与CRIT-LINE(BV%(CLM)之间的关系; Hema Metrics,Kaysville,然后评估(美国UT)。在30例血液透析患者中​​,BV%(BVM)与BV%(HT)和BV%(BVM)与BV%(CLM)密切相关(n = 30,r = 0.967,P <0.001,和n = 36,r = 0.7867,P <0.001)。其次,BV%数据是从一个卫星血液透析中心对26名受试者进行的464例治疗病例中获得的,这些患者的体重被认为是临床上合适的。确定了BV%水平的公式(通过血液透析治疗结束时的体重变化百分比标准化:BW%end)。最后,我们重新验证了上述级别的可靠性。在七个血液透析中心对201名体重被认为合适的患者进行了总计1126次测量。然后重新计算新的理想水平。因此,我们得出结论,BVM是监测血液透析治疗中BV%的足够准确的方法。大多数控制良好的血液透析患者显示出相同的BV%/ BW%end模式。在血液透析期间监测BV%对确定干重(DW)很有帮助。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号