首页> 外文期刊>Theriogenology >Evaluation of feline uterine and umbilical arteries blood flow in a pharmacologically induced abnormal gestation model
【24h】

Evaluation of feline uterine and umbilical arteries blood flow in a pharmacologically induced abnormal gestation model

机译:药理性异常妊娠模型对猫子宫和脐动脉血流的评估

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to describe resistance index (RI) and systolic/diastolic ratio (S/D ratio) of uterine and umbilical arteries in an experimental model of abnormal pregnancy in felids. On days 30 to 35 (32 +/- 2.9) after mating, 20 domestic short-hair pregnant queens were randomly assigned to one of the following treatment groups: a treated group (TG; n = 8), which received 10 mg/kg of aglepristone subcutaneously twice, 24 hours apart, and a control nontreated group (CG; n = 12). M-mode and Doppler ultrasonographic evaluations were performed at the initiation of the treatment (Day 0) and then every other day during 8 days. In both groups, uterine and umbilical arteries were evaluated by Doppler ultrasound, whereas fetal heart rate was assessed by M-mode ultrasound. Resistance index of uterine artery augmented in TG from Day 2 onward, conversely it decreased in CG (P 0.01). On Day 8, RI values were 0.64 +/- 0.05 vs 037 +/- 0.01 for TG and CG, respectively. Additionally, S/D ratio of the same artery presented an increase in TG, whereas this ratio diminished in CG (P 0.01). On Day 8, this parameter showed values of 2.98 +/- 0.4 vs 1.62 +/- 0.06 for TG and CG, respectively. Resistance index of umbilical artery remained almost unchanged in TG from Day 6 onward, whereas it progressively decreased in CG throughout the course of the study (P 0.05). On Day 8, RI were 0.89 +/- 0.04 and 0.82 +/- 0.01, for TG and CG, respectively. Furthermore, on Day 8, S/D ratio of umbilical artery progressively diminished in CG but not in TG (P 0.01), being 14.7 +/- 9.1 vs 5.9 +/- 0.3 for TG and CG, respectively. Fetal heart rate was higher in TG than in CG (P 0.05). Group differences in Doppler parameters appeared on Day 2, when the other clinical or ultrasonographic signs were still absent. It is concluded that blood flow of the uterine and umbilical arteries differed between these normal and abnormal gestations predicting an adverse obstetric outcome. (C) 2016 Elsevier Inc. All rights reserved.
机译:这项研究的目的是描述猫异常怀孕的实验模型中子宫和脐动脉的抵抗指数(RI)和收缩/舒张比(S / D比)。在交配后第30至35天(32 +/- 2.9),将20头国内短发怀孕的女王/王后随机分配到以下治疗组之一:治疗组(TG; n = 8),接受10 mg / kg皮下注射两次aglepristone,间隔24小时,以及对照组(CG; n = 12)。在治疗开始时(第0天)进行M型和多普勒超声检查,然后在8天内每隔一天进行一次。两组均通过多普勒超声评估子宫和脐动脉,而通过M型超声评估胎儿心率。从第2天开始,TG增强了子宫动脉的抵抗指数,而CG则降低了(P <0.01)。在第8天,TG和CG的RI值分别为0.64 +/- 0.05和037 +/- 0.01。此外,同一条动脉的S / D比值显示TG升高,而CG值则下降(P <0.01)。在第8天,此参数显示的TG和CG值分别为2.98 +/- 0.4和1.62 +/- 0.06。从第6天开始,TG的脐动脉阻力指数几乎保持不变,而在整个研究过程中CG的阻力指数逐渐降低(P <0.05)。在第8天,TG和CG的RI分别为0.89 +/- 0.04和0.82 +/- 0.01。此外,在第8天,CG中脐动脉的S / D比逐渐降低,而TG中则没有(P <0.01),TG和CG分别为14.7 +/- 9.1和5.9 +/- 0.3。 TG的胎心率高于CG(P <0.05)。第2天出现多普勒参数的组差异,而其他临床或超声检查征象仍不存在。结论是,这些正常妊娠和异常妊娠之间子宫和脐动脉的血流不同,预示着不良的产科预后。 (C)2016 Elsevier Inc.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号