首页> 外文期刊>Therapeutic Drug Monitoring >False-positive serum tricyclic antidepressant concentrations using fluorescence polarization immunoassay due to the presence of hydroxyzine and cetirizine.
【24h】

False-positive serum tricyclic antidepressant concentrations using fluorescence polarization immunoassay due to the presence of hydroxyzine and cetirizine.

机译:由于存在羟嗪和西替利嗪,使用荧光偏振免疫分析法测定的假阳性血清三环类抗抑郁药的浓度。

获取原文
获取原文并翻译 | 示例
       

摘要

A recent report indicates that hydroxyzine and its active metabolite cetirizine interfere with the PENTINA carbamazepine assay. The potential interference of hydroxyzine and cetirizine with the fluorescence polarization immunoassay (FPIA) and CEDIA assay of carbamazepine as well as with the fluorescence polarization immunoassay of tricyclic antidepressants (TCA) was studied. Aliquots of drug-free serum pools were supplemented with various concentrations of hydroxyzine and cetirizine representing therapeutic, mild to moderate toxic as well as very toxic concentrations. Then apparent carbamazepine and TCA concentrations were measured by immunoassays. Although no interference of hydroxyzine and cetirizine was observed with carbamazepine assays (FPIA and CEDIA), significant apparent TCA concentrations were observed when aliquots of drug-free serum were supplemented with hydroxyzine or cetirizine. Mathematical formula was devised to predict hydroxyzine and/or cetirizine concentration in serum based on observed apparent TCA levels. Hydroxyzine and cetirizine also falsely increased total TCA values when aliquots of serum pool prepared from patients receiving TCA were further supplemented with these drugs. In conclusion, hydroxyzine and cetirizine do not interfere with the FPIA and CEDIA carbamazepine assays but interfere with the measurement of total TCA using the FPIA.
机译:最近的报告表明,羟嗪及其活性代谢产物西替利嗪会干扰PENTINA卡马西平的测定。研究了羟嗪和西替利嗪对卡马西平的荧光偏振免疫分析(FPIA)和CEDIA分析以及三环抗抑郁药(TCA)的荧光偏振免疫分析的潜在干扰。在无药血清池的等分试样中补充各种浓度的羟嗪和西替利嗪,分别代表治疗性,中度至中度毒性以及极度毒性。然后通过免疫测定法测定表观的卡马西平和TCA浓度。尽管用卡马西平测定(FPIA和CEDIA)未观察到羟嗪和西替利嗪的干扰,但是当等分无药血清补充羟嗪或西替利嗪时,观察到明显的TCA浓度。基于观察到的表观TCA水平,设计了数学公式来预测血清中的羟嗪和/或西替利嗪浓度。当从接受TCA的患者准备的等分试样的血清库中进一步补充这些药物时,羟嗪和西替利嗪也会错误地增加总TCA值。总之,羟嗪和西替利嗪不会干扰FPIA和CEDIA卡马西平的测定,但会干扰使用FPIA的总TCA的测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号