The objective of this study was to evaluate the analytical performance of 2 new tacrolimus immunoassays (Dade Dimension Xpand and Abbott ARCHITECT) for therapeutic drug monitoring as possible replacements for the current method in our laboratory, the Abbott IMx tacrolimus assay. Attending physicians at our institute desire to minimize calcineurin inhibitor therapy in kidney allograft recipients to prolong graft survival and improve the quality of life of their patients. Proposed future target trough levels of tacrolimus in whole blood are in the range of 2-4 ng/mL, which requires an assay with a limit of quantification (LOQ) below this range, ideally around 1 ng/mL (European Consensus Recommendation from the Committee on Tacrolimus Optimization). Method comparison analysis of the Dade and ARCHITECT assays showed good correlation to the IMx assay, with correlation coefficients of 0.94 and 0.96, respectively. Both assays reported tacrolimus concentrations lower on average than IMx as demonstrated by slopes of 0.83 (Dade) and 0.93 (ARCHITECT). LOQ for both Dade instruments tested was >4 ng/mL, whereas the LOQ for the ARCHITECT i2000 and i1000 instruments was 0.8 and 0.5 ng/mL, respectively (upper 95% confidence limit). Values reported from both Dade instruments were observed to shift over time, whereas the values on the IMx and ARCHITECT instruments were stable. The Abbott ARCHITECT Tacrolimus assay is a sensitive and precise assay that meets the new LOQ recommendation, 1 ng/mL, for monitoring tacrolimus in whole blood.
机译:这项研究的目的是评估两种新的他克莫司免疫测定法(Dade Dimension Xpand和Abbott ARCHITECT)用于治疗性药物监测的分析性能,以替代我们实验室当前的方法Abbott IMx他克莫司测定法。我们研究所的主治医生希望尽量减少肾移植患者的钙调神经磷酸酶抑制剂治疗,以延长移植物的存活时间并改善其患者的生活质量。拟议的他克莫司在全血中的未来目标谷值水平在2-4 ng / mL的范围内,这需要定量限(LOQ)低于该范围的测定,理想的是在1 ng / mL左右(欧洲共识建议)。他克莫司优化委员会)。 Dade和ARCHITECT分析的方法比较分析显示与IMx分析具有良好的相关性,相关系数分别为0.94和0.96。两种测定均报告他克莫司的平均浓度低于IMx,斜率分别为0.83(大德)和0.93(ARCHITECT)。两种测试的Dade仪器的LOQ均大于4 ng / mL,而ARCHITECT i2000和i1000仪器的LOQ分别为0.8和0.5 ng / mL(95%置信度上限)。观察到两种Dade仪器报告的值都随时间变化,而IMx和ARCHITECT仪器上的值是稳定的。雅培ARCHITECT他克莫司测定法是一种灵敏而精确的测定法,符合用于监测全血中他克莫司的新LOQ推荐值1 ng / mL。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号