首页> 外文期刊>The Paton Welding Journal >MONITORING OF CORROSION OF PIPELINES OF COOLING SYSTEM OF AUTOMOBILE GAS-FILLING COMPRESSOR STATIONS
【24h】

MONITORING OF CORROSION OF PIPELINES OF COOLING SYSTEM OF AUTOMOBILE GAS-FILLING COMPRESSOR STATIONS

机译:汽车充气压缩机站冷却系统管道的腐蚀监测。

获取原文
获取原文并翻译 | 示例
           

摘要

Analysis of peculiarities of corrosion processes was made in carbon steel and its welded joints in cooling liquids of TOSOL type used in cooling systems of automobile gas-filling compressor stations (AGFCS). A method of monitoring the instant rate of corrosion in metal of pipes and welded joints in the cooling system at AGFCS, based on the method of polarization resistance, is offered. Sensors have been developed for estimation of corrosion rate in carbon steel and its welded joints in cooling liquid.
机译:分析了碳钢及其在汽车充气压缩机站(AGFCS)冷却系统中使用的TOSOL型冷却液中的焊接接头的腐蚀过程的特殊性。提供了一种基于极化电阻的方法来监控AGFCS冷却系统中管道和焊接接头的金属即时腐蚀速率的方法。已经开发出用于估计碳钢及其在冷却液中的焊接接头的腐蚀速率的传感器。