...
首页> 外文期刊>The Journal of Physiology >Vesicles in snake motor terminals comprise one functional pool and utilize a single recycling strategy at all stimulus frequencies.
【24h】

Vesicles in snake motor terminals comprise one functional pool and utilize a single recycling strategy at all stimulus frequencies.

机译:蛇形机动终端中的囊泡包含一个功能池,并且在所有刺激频率下均采用一种回收策略。

获取原文
获取原文并翻译 | 示例

摘要

At a variety of fast chemical synapses, spent synaptic vesicles are recycled via a large 'reserve' vesicle pool at high stimulus frequencies, and via fast 'local cycling' near release sites (e.g. 'kiss and run' transmitter release) at low stimulus frequencies. We have investigated recycling at the snake neuromuscular junction (NMJ), specifically seeking evidence for local cycling. Activity-dependent staining and destaining of the endocytic probe FM1-43 were directly compared to transmitter release over a range of stimulus frequencies. We found a fixed proportionality between staining/destaining and summed endplate potentials (EPPs) representing total transmitter release. There was no direct dependence of staining or destaining on stimulus frequency, as would be expected if local cycling (and consequent altered FM1-43 retention) were more prevalent at one frequency than another. In other experiments the drug vesamicol was used to abolish refilling of vesicles with transmitter, thereby blocking EPPs contributed by recycled vesicles. Control and vesamicol-treated NMJs had identical quantal content for the first 10 min of 1 Hz stimulation. Afterwards EPP amplitudes at vesamicol-treated NMJs declined at a rate consistent with use of a large pool containing approximately 130,000 vesicles. Finally, calibrated paired stimulations show that regenerated vesicles have poorer than random probability of re-release. Our findings are inconsistent with local cycling and suggest that the snake motor terminal utilizes exclusively a single large vesicle pool.
机译:在各种快速化学突触中,用过的突触小泡通过高刺激频率的大型“储备”囊泡池进行再循环,并在低刺激频率下通过释放位置附近的快速“局部循环”(例如“亲吻和奔跑”变送器释放)进行回收。 。我们已经研究了蛇神经肌肉接头(NMJ)处的回收,特别是在寻找当地自行车的证据。将内吞探针FM1-43的活动依赖性染色和脱色直接与一系列刺激频率下的递质释放进行比较。我们发现在染色/褪色与代表总变送器释放的终板总电位(EPP)之间存在固定比例。没有染色或染色对刺激频率的直接依赖性,如果局部循环(以及随之而来的FM1-43保留改变)在一个频率比另一个频率更普遍的话,这是可以预期的。在其他实验中,药物维他命醇用于取消用递质重新填充囊泡,从而阻止由再循环囊泡贡献的EPP。在1 Hz刺激的前10分钟内,对照品和接受vesamicol处理的NMJ的定量含量相同。之后,经维他命醇处理的NMJ的EPP振幅下降的速率与使用包含约130,000个囊泡的大池的使用速率一致。最后,校准的配对刺激显示,再生的囊泡比随机释放的概率差。我们的发现与当地的自行车运动并不一致,表明蛇形运动终端仅利用一个大的囊泡池。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号